33
13.3
ONE trigger mode
When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start. At the trigger signal
falling edge, the video data are transmitted.
PartialScanMode OFF
PartialScanMode ON (Note 14.2.1)
BinningVertical
OFF
BinningVertical
ON
BinningVertical OFF
BinningVertical ON
①
990H
503H
(2+
⌈
(12+OFFSET)/9
⌉
)
+9+HEIGHT
+
⌈
(967-OFFSET
-HEIGHT)/9
⌉
+1) H
(2+
⌈
(8+OFFSET)/9
⌉
)
+9+
⌈
HEIGHT/2
⌉
+
⌈
(962-OFFSET
-HEIGHT)/9
⌉
+1) H
②
32.2H
23.2H
(2+
⌈
(12+OFFSET)/9
⌉
) H
(2+
⌈
(8+OFFSET)/9
⌉
) H
③
960H
480H
(9+HEIGHT) H
(9+
⌈
(HEIGHT/2)
⌉
) H
(Note 14.3.1)
⌈ ⌉
is Ceiling function.
1 H = 33.6μs
More than ①
②
③
Trigger
input(POSI)
High
Low
Shutter time
Shutter time
(Camera setting value)
Data output
More than 10μs
FLASH OUT
(10pin-OUT)
VD
(10pin-OUT)
3H
FVAL
0.45μs 9.8μs
Содержание HV-F130SCL