8
-AES MODE- : selects a control mode of AES (Automatic electronic shutter).
OFF (Factory setting)
: Not perform AES (using manual setting of OFF/PRESET/VARIABLE).
ON
: An electronic shutter is controlled automatically
so that the brightness of the output image will be practical level.
-AES MIN- : setting to shortest speed limit of an AES.
1/30sec to 1/100,000sec : AES range for minimum exposure limit. (Factory setting : 1/100,000sec)
When become setting AES MAX < MIN, it effects same value on AES MAX.
-AES MAX- : setting to longest speed limit of an AES.
1/30sec to 1/100,000sec : AES range for maximum exposure limit. (Factory setting : 1/30sec)
When become setting AES MAX < MIN, it effects same value on AES MIN.
9.3
GAIN LEVEL : Setting of electrical sensitivity
-Value- : Adjust MANUAL gain level
0 (Factory setting) to 12.04dB
: Set MANUAL gain when AGC is OFF.
Adjustable from 0 to 12.04dB in 512 steps.
-AGC MODE- : selects a control mode of AGC (Automatic gain control)
OFF (Factory setting)
: Not perform AGC (using manual setting of VALUE).
ON
: A gain of electrical sensitivity is controlled automatically
so that the brightness of the output image will be
practical level.
-AGC MIN- : setting to lowest gain limit of an AGC.
0 to 12.04dB
: AGC range for minimum gain limit. (Factory setting : 0dB)
When become setting AGC MAX < MIN, it effects same value on AGC MAX.
-AGC MAX- : setting to highest gain limit of an AGC.
0 to 12.04dB
: AGC range for maximum gain limit. (Factory setting : 12.04dB)
When become setting AGC MAX < MIN, it effects same value on AGC MIN.
9.4
ALC LEVEL : setting to practical level for an ALC (Auto level control)
It is adjustable practical level for the brightness of the output image.
When AES MODE or AGC MODE is ON, those use this practical level.
0 to 255
: Setting value toward 0 side make a dark image and 255 side make a bright image. (Factory setting : 128).
9.5
BRIGHTNESS : Adjust offset level
-128 to 127
: Set in 256 steps. (Factory setting:0)
9.6
GAMMA : Setting of gamma correction
-MODE- : Selection of mode
OFF (Factory setting)
: Not perform gamma correction.
ON 1
: When LEVEL value is 255, that makes gamma = 0.45 so that normal gamma curve.
ON 2
: Dark side expand less than ON1, so that makes a S line gamma curve.
-LEVEL- : Adjust gamma correction
0 (Factory setting) to 255 : Set gamma curve in 256 steps.
Setting value 0 makes gamma = 1.0 that nearly equal OFF.
Setting value 255 makes gamma = 0.45 so that normal gamma curve. (ON 1)
Содержание HV-F130SCL