13
9.18
BINNING : Setting of Vertical Pixel Mix
OFF (Factory setting) : Not perform vertical pixel mix.
ON
: Vertical pixel mix doing that make approximately double frame rate.
9.19
PARTIAL : Setting for Partial Scan
-MODE - : Selection of mode
OFF
: Not perform partial scan.
ON (Power On status) : Perform partial scan.
-START- : Starting line of partial scan
0 to 860
: Setting value is a starting line of partial scan on the standard picture.
-WIDTH- : Vertical line width of partial scan
100 to 960
: Setting value is a vertical line number of partial scan.
=== Notes ===
The total value of the START and WIDTH of partial scan is within 960.
The other is automatically adjusted so as not to exceed the 960 in the setting.
9.20
TEST PATTERN : Setting of Video test pattern
OFF (Factory setting) : Test pattern OFF.
H-RAMP
: Horizontal RAMP signal.
COLOR BAR
: Color bar signal.
9.21
MEMORY : Save or load the camera setting
-LOAD- : Load memory
DEFAULT (Factory setting): Return to the factory setting..
FILE 1 to FILE 4 : Load the file number 1 to 4
-SAVE- : Save memory
FILE 1 to FILE 4 : Save current settings to the file number 1 to 4
=== Notes ===
Last loading file number will become using for next setting to power supply startup.
9.22
FACTORY SETTING : File data initialize will become returned to the factory setting
File data initialize will become returned to the factory setting.
All files (FILE 1 to FILE 4) will be initialized as same as DEFAULT.