3. Creating an HDLM Environment
71
Note the following in an EM64T/AMD64 environment:
•
HDLM supports an environment where an EM64T/AMD64 kernel is
installed on a system that uses an Intel CPU or AMD Opteron CPU.
•
In an EM64T/AMD64 environment, the RPM (Red Hat Package Manager)
packages listed below are required. Install these RPM packages before
installing HDLM:
- +-RPM package version.i386.rpm
- libgcc-RPM package version.i386.rpm
- glibc-RPM package version.i686.rpm
RPM package version depends on the OS version you are using.
3.1.2 Storage Systems Supported by HDLM
The following shows the storage systems that HDLM supports.
(1) Storage Systems
The following storage systems are supported by HDLM:
If an FC-SAN is used:
•
Hitachi AMS2000/AMS/WMS/SMS series
•
Hitachi NSC55
•
Hitachi TagmaStore Universal Storage Platform 100
•
Hitachi TagmaStore Universal Storage Platform 600
•
Hitachi TagmaStore Universal Storage Platform 1100
•
Hitachi Universal Storage Platform V
•
Hitachi Universal Storage Platform VM
•
Hitachi Virtual Storage Platform
•
HP StorageWorks P9500 Disk Array
•
HP XP128/HP XP1024/HP XP10000/HP XP12000/HP XP20000/HP XP24000
•
Lightning 9900 series
•
Lightning 9900V series
•
SVS
•
Thunder 9500V series
If an IP-SAN is used:
•
Hitachi AMS2000 series
Содержание Dynamic Link Manager
Страница 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Страница 4: ......
Страница 16: ......
Страница 79: ...2 HDLM Functions 55 Figure 2 16 Example System Configuration Using HDLM and Global Link Manager ...
Страница 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Страница 162: ...3 Creating an HDLM Environment 138 ...
Страница 272: ...3 Creating an HDLM Environment 248 Example of executing the parted command IA32 IPF or EM64T AMD64 ...
Страница 294: ...3 Creating an HDLM Environment 270 see whether the HDLM device corresponding to the SCSI device has been created ...
Страница 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Страница 352: ......
Страница 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Страница 375: ...4 HDLM Operation 351 ...
Страница 410: ......
Страница 546: ......
Страница 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Страница 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Страница 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Страница 707: ...8 Messages 683 KAPL15404 W The HDLM Manager was executed by the user who does not have the authority ...
Страница 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Страница 714: ......
Страница 738: ......