8. Messages
564
separated by period)
aa...aa
: Host ID (host port number) (decimal number)
bb...bb
: Channel number (bus number) (decimal number)
cc...cc
: Target ID (target ID) (decimal number)
dd...dd
: LUN (host LU number) (decimal number)
Action
Please perform the following steps.
1.
Note down the HCTL values of the SCSI device as shown in the error
messages.
2.
Obtain the corresponding HDLM device name for the HCTL value noted in
step 1 by using the following command:
# dlmcfgmgr -v
3.
Unregister the HDLM devices by using the following command:
# dlmcfgmgr -u
logical-device-file-name-of-the-HDLM-device
4.
Reconfigure the HDLM by using the following command:
# dlmcfgmgr -r
KAPL05708-E
The system retried to allocate memory
aa...aa
times, but the
retries failed. (
bb...bb
:
cc...cc
)
Details
aa...aa
: Memory allocation retry count (decimal number)
bb...bb
: File ID, line number (hexadecimal number)
cc...cc
: Memory allocation size (hexadecimal number)
Action
Execute the utility for setting HDLM driver option (
dlmsetopt
) and increase the
number of retries for allocating memory. For details on the
dlmsetopt
utility, see
7.6 dlmsetopt Utility for Setting HDLM Driver Options
. Increase system
memory. Stop any unnecessary processes. If the problem is not solved, execute
the
DLMgetras
utility for collecting HDLM error information, and then contact
your HDLM vendor or the maintenance company if there is a maintenance
contract for HDLM. For details on the
DLMgetras
utility, see
7.2 DLMgetras
Utility for Collecting HDLM Error Information
.
KAPL05709-I
The system will retry to allocate memory
aa...aa
times.
Содержание Dynamic Link Manager
Страница 1: ...Hitachi Dynamic Link Manager Software User s Guide for Linux R 3000 3 F04 60 E ...
Страница 4: ......
Страница 16: ......
Страница 79: ...2 HDLM Functions 55 Figure 2 16 Example System Configuration Using HDLM and Global Link Manager ...
Страница 154: ...3 Creating an HDLM Environment 130 Figure 3 1 Flow of HDLM Environment Setup ...
Страница 162: ...3 Creating an HDLM Environment 138 ...
Страница 272: ...3 Creating an HDLM Environment 248 Example of executing the parted command IA32 IPF or EM64T AMD64 ...
Страница 294: ...3 Creating an HDLM Environment 270 see whether the HDLM device corresponding to the SCSI device has been created ...
Страница 309: ...3 Creating an HDLM Environment 285 Figure 3 33 Example of Creating an ext2 File System ...
Страница 352: ......
Страница 362: ...4 HDLM Operation 338 A Fibre Channel switch s zone setting is changed ...
Страница 375: ...4 HDLM Operation 351 ...
Страница 410: ......
Страница 546: ......
Страница 549: ...8 Messages 525 HDLM driver filter component HDLM alert driver HDLM management target ...
Страница 590: ...8 Messages 566 dd dd Maintenance information hexadecimal number Action None ...
Страница 594: ...8 Messages 570 aa aa Name of file where error was detected Action Reinstall an HDLM ...
Страница 707: ...8 Messages 683 KAPL15404 W The HDLM Manager was executed by the user who does not have the authority ...
Страница 713: ...8 Messages 689 utility see 7 2 DLMgetras Utility for Collecting HDLM Error Information ...
Страница 714: ......
Страница 738: ......