54
7. WIRING [Wiring Connection Diagram]
7.3.4 Wiring Connection Diagram 2 (200WN, 240WN, 460V Class (2/2))
CE
CE
CE
R2
S2
T2
17
S3
RY21X
S2
T2
R2
46
42
46
RP
SP
115V
RS
S2
460V
TR 1kV
A
38
39
52
AK
D1
32
33
Y52A
CE
(G)
TB2
41
42
Y52A
TH2
TH3
PS1
PS2
R4
(G)
(L)
(K)
CT
to PWB2 T
AB2
to PWB2 T
AB1
Y1
Y2
Y3
REMOTE STOP
REMOTE ST
ART
DC24V
to LCD CN9
to P
WB2 CN1
to P
WB2 CN2
Y2
TB1
Y3
ST
ART
Y1
COM1
STOP
24L
CN10
CN16
CN9
CN1
24V2
24V1
CN15
COM2
PS1
TH1
PS2
TH2
CN24
TH3
SUCF
UNL REM
CN13
CN3
TR OUT
C
N5
DC24V(+)
C
N4
CN11
C
N7
Y52C
Y20
Y42
Y21
Y6
CN6
Y52
C
N8
CN12
CN2
ANS
O
VLD
CN14
DSA
REVERSE PHASE
CN21 DU
AL
DC24V INPUT
P
WB1(HC55)
SW1
SW2
CHG
A
B
63SV
DS1-1
DS1-2
42
6
200kW 460V/352A 240kW 460V/399A
200kW 460V/213A 240kW 460V/242A
52
IM
1
37
36
88F
52
34
31
42
52
6
16
6
15
49M
2
42
CE
CE
8
S3
11
10
13
14
49M
1
8A
88F1
CE
CE
CE
CE
CE
1
2
CN39
CE
CE
FM2
1
2
CN38
CE
CE
FM1
88F
49M2
1.1A
IM
2
0.4kW
460V/1.0A
C
SHORT CIRCUIT
DURING REMOTE OPERA
TION,
REMO
VE SHORT CIRCUIT WIRES.
500ms OR MORE
ONE
-SHOT INPUT
RELA
Y OUTPUT
to TB3
SP1 5A
60W
(+)
(−)
24V
24E
C
DA
A
VR1
(G)
S2
TB2
R2
CE
CE
R4
90W
(+)
(−)
A
VR2
(G)
C
DA
X
X
20A
20W
5A
CB2
CLASS 1 CONTROL CIRCUIT
ES
to LCD CN7
to TB3
C
R
CD
D
C
T2A
CB1
15A
C
CN USP
4321
T1
T1A
T1A
S1
SP
S1A
R1
RP
R1A
(G)
(−)
A
VR3
DA
1
C1
(+)
(G)
30W
Y
R2
ES
R4
C
LF
Y52A
Y52A
43
44
46
45
C
DA
C1
DA
1
Y
C
20UM
TB2
CE
37
CE
37
S3
S3
CE
CE
20U3
20U4
CE
CE
CE
CE
CE
CE
S2
R3V
R3V
S2
R3V
S2
20US
20U1
20U2
CE
20D2
CE
S2
R3D
CE
20D1
CE
R3D
S2
C
CE
S3
CE
S3
S3
35
18
CE
6
CE
SK
CE
6
35
18
S3
RY 21X
CE
R3
S2
3
φ
AC460V 60Hz
B
OTH MAIN DISCONNECT MEANS AND BRANCH CIRCUIT
PROTECTION SHALL BE PRO
VIDED B
Y THE CUSTOMER.
IN ADDITION,MAIN DISCONNECT MEANS SHALL BE PRO
VIDED
ON THE LINE SIDE OF THE BRANCH CIRCUIT PROTECTION. FOR USE ON A SOLIDL
Y GROUNDED WYE SOURCE ONL
Y.
TB0
(G)
R
S
T
R
S
T
49M1
YZX
UVW
V2 W2 U2
W1
V1
U1
UVW
1
2
(R)
(W)
(B)
(R)
(W)
(B)
1 2
1 2
1 2
1 2 3 4
1 2 3 4
1 2 3 4 5
1 2
CN19
CN20
CN23
CN21
CN17
CN18
CN25
OPE2
OPE1
123
123
1
2
3
4
1
9
1 1
3
1
8
1
5
REMOTE SET
TING
EXTERNAL L
OAD/UNL
OAD
REMOTE OPERA
TION
DRYER ANSWER
OPERA
TION ANSWER
O
VER L
OAD
O
VER L
OAD
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10
4321
4
3
2
1
531
31
31
7
5
3
1
531
531
S K
S K
S3
18
35
S3
6
S3
S2
R3
Y42
α
1 3 5 7
CA
UTION DRY "a" CONT
ACT(0.5A)
SHUTDOWN DRY "a" CONT
ACT(0.5A)
EX
TERNAL L
O
AD/UNL
O
AD :
"a" CONT
ACT(0.5A)
REMOTE SET
TING : "a" CONT
ACT(0.5A)
OPERA
TION DRY "a" CONT
ACT(0.5A)
S K
UNL
OAD
STOP
C
DA1
DA
S2
R4
R2
41
42
S2
43
44
DA
45
46
DA
REFER TO THE WIRING DIAGRAM 2
REFERENCE:
REFER TO THE INSIDE OF THE AIR COMPRES
SOR, BUT NOT IN THE
CONTROL P
ANEL
REFER TO CONPONENTS THA
T ARE
EXTERNAL TO THE AIR COMPRES
SOR
PACK
AGE
S K
S K
S K
S K
NOTES: 1. SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED B
Y HIT
ACHI IS THE
RESPONSIBILITY OF THE CUSTOMER.
2. RA
TED DRY CONT
ACT IS AC110V 0.5A (MAX)
3. SIGNAL INPUT FOR REMOTE OPERA
TION IS DC24V
4. BRANCH CIRCUIT PROTECTION SHALL BE 460V/700A(200/240kW) MAX
.
UL LISTED DU
AL ELEMENT TIME DELA
Y BRANCH CIRCUIT TYPE FUSES.
5. FIELD WIRING CONDUCTOR SHALL BE 300MCM×2. 6. USE LISTED PRES
SURE TERMINAL CONDUCTORS SUCH AS A RING TYPE
.
7. CONNECT MAXIMUM 3 FIELD WIRING CONDUCTOR TO ONE CONDUIT
.
SYMB
OL
IM1 IM1 52 42 6 88F 49M1 49M2 PWB1 PWB2 LCD 20U1 20U2 20U3 20U4 20US 63SV PS1 PS2 TH2 TH3 TB0 TB1-3 CT
PARTS NAME MAIN MOTOR F
AN MOTOR
MAIN ELECTROMAGNETIC CONT
ACTOR
ELCTROMAGNETIC CONT
ACTOR FOR
△
ELCTROMAGNETIC CONT
ACTOR FOR
Y
ELCTROMAGNETIC CONT
ACTOR FOR F
AN
THERMAL RELA
Y FOR MAIN MOTOR
THERMAL RELA
Y FOR F
AN MOTOR
CONTROL PC B
OARD
DISPLA
Y PC B
OARD
LCD MONITOR
SOLENOID V
AL
VE
SOLENOID V
AL
VE
SOLENOID V
AL
VE
SOLENOID V
AL
VE
SOLENOID V
AL
VE
PRES
SURE DIFFERENTIAL SWIT
CH
PRES
SURE SENSOR (1ST DIS.)
PRES
SURE SENSOR (2ND DIS.)
THERMISTOR (2ND SUCTION)
THERMISTOR (2ND DIS.)
TERMINAL BL
OCK
TERMINAL BL
OCK
CURRENT TRANSFORMER
SYMB
OL
DSA
R
SW1,2 GHG
SK 46
CB1,2 SP1
ES
FM1,2
CN DS CE D1 TR
AVR1,2 Y52A RY21X 20D1,2 20UM
LF 20A 20W
PARTS NAME
LIGHTNING ARRESTER
RESIST
ANCE
DIP SWIT
CH
CHARGE LAMP
SURGE AB
SORBER
REVERSE PHASE RELA
Y
CIRCUIT BREAKER
SUPPLEMENT
ARY PROTECTOR
EMERGENCY STOP
FA
N
CONNECTOR
PL
UG IN CONNECTOR
CONNECTOR
DIODE
TRANSFORMER
AUTOMA
TIC VOL
TAGE REGULA
TOR
RELA
Y
RELA
Y
SOLENOID V
AL
VE FOR CONDENSA
TE
SOLENOID V
AL
VE FOR OMR
LINE FIL
TER
MOTORIZED ISOLA
TION V
AL
VE FOR AIR
MOTORIZED ISOLA
TION V
AL
VE FOR W
ATER
SYMB
OL
Y1
Y2
Y3
Y52
Y6
Y42
Y20
Y21
Y52A
DESCRIPTION
OPERA
TION RELA
Y
CA
UTION OUTPUT
SHUTDOWN OUTPUT
OPERA
TION RELA
Y
RELA
Y FOR
Y
RELA
Y FOR
△
LOAD/UNL
OAD RELA
Y
CONDENSA
TE RELA
Y
OPERA
TION RELA
Y
ACTION
ON A
T OPERA
TION
(L
OAD/UNL
OAD/A
UTO STOP)
ON A
T CA
UTION
ON A
T SHUTDOWN
ON A
T MAIN MOTOR RUNNING
ON A
T RUNNING (
Y )
ON A
T RUNNING (
△
)
ON A
T L
OAD
(2 SECOND LA
TER AF
TER
△
)
ON
AT CONDENSA
TE DISCHARGE
ON A
T MAIN MOTOR RUNNING
OFF A
T TO SECONDS LA
TER
AF
TER MAIN MOTOR STOP
1
2