-19-
Tightening torque
Confirmation after reassembly
Apply Nippeco SEP-3A to the following points.
• Sloped portion of the Lever (C)
[22]
• O-Ring
[9]
• Inner periphery of the Swing Roller
[14]
• 8-mm diameter portion of the Recipro Plate (F)
[28]
• Tooth surface of the Gear (F)
[32]
• Polished portion of the Plunger (F)
[12]
• Pinion section of the Armature Ass’y
[37]
• Inner periphery of the Metal (B)
[10]
• Outer periphery of the Connector Pin (F)
[13]
• Swing Roller
[14]
, Plunger (F)
[12]
, and Gear (F)
[32]
inside the Gear Cover (F)
[4]
-- Fill a lubricator with 45 g of lubricant to lubricate these parts.
• Slotted Hd. Screw (Seal Lock) M4 X 10
[36]
------------------------------------ 1.8±0.4 N•m (18±4 kgf•cm)
• Tapping Screw (W/Flange) D4
[50] [58]
----------------------------------------- 2.0±0.5 N•m (20±5 kgf•cm)
• Nylock Bolt (W/Flange) M4 X 12
[25]
--------------------------------------------- 3.6±0.7 N•m (37±7 kgf•cm)
• Special Bolt M5
[21]
------------------------------------------------------------------ 5.9±1.5 N•m (60±15 kgf•cm)
• Machine Screw (W/Washers) M5 X 60 (Black)
[47]
--------------------------- 2.5±0.5 N•m (25±5 kgf•cm)
• Hex. Hd. Tapping Screw D5 X 55
[39]
-------------------------------------------- 3.4±0.7 N•m (35±7 kgf•cm)
• Nylock Bolt (W/Flange) M5 X 12
[15]
--------------------------------------------- 5.9±1.5 N•m (60±15 kgf•cm)
• Nylock Bolt (W/Flange) M6 X 35
[16]
--------------------------------------------- 11.8±2.0 N•m (120±20 kgf•cm)
• Lock Nut M5
[11]
----------------------------------------------------------------------- 3.4±0.7 N•m (35±7 kgf•cm)
1. Internal wire precautions
Do not peel an excessive length of covering from each lead wire joint. Also be careful to avoid getting the
lead wires caught in the joint between the handles.
2. Insulation tests
After disassembly or repair, measure the insulation resistance and conduct a dielectric strength test
(voltage breakdown test).
• Insulation resistance
7 M
:
min.
• Dielectric strength
2500 V for 1 minute --- 110 to 120 V
4000 V for 1 minute --- 220 to 240 V
3. No-load current value
The no-load current value derived from 30-minute continuous operation at 50/60 Hz must be as indicated
below.
• 110 V --- 4.4 A max.
• 120 V --- 4.1 A max.
• 220 V --- 2.2 A max.
• 230 V --- 2.2 A max.
• 240 V --- 2.1 A max.
Application of lubricant