-14-
Fig. 9
Fig. 10
7. Disassembling the Handle (G) and Switch (Fig. 9)
Note the two lead wires connected to the Stator Ass’y
[40]
and the two lead wires connected to the Cord
[61]
. Loosen the machine screw on the Switch
[53]
. The Switch
[53]
can now be removed from the Handle
(G)
[57]
. Also remove the two Tapping Screws (W/Flange) D4 x 16
[58]
, and then remove the Cord Clip
[59]
, Cord
[61]
, and Cord Armor
[60]
from the Handle (G)
[57]
.
8. Disassembling the Housing and Stator Ass’y (Fig. 10)
Remove the brush terminal of the Stator Ass’y
[40]
from the Brush Holder
[46]
, remove the two Hex. Hd.
Tapping Screws D5 x 55
[39]
, and then separate the Stator Ass’y
[40]
from the Housing
[43]
. Also use a
flat-blade screwdriver or similar tool to push the Brush Holder
[46]
out of the Housing
[43]
. (Note that the
Brush Holder
[46]
is not secured with a screw or adhesive.)
Hex. Hd. Tapping Screw D5 x 55
[39]
Housing
[43]
Handle (G)
[57]
Stator Ass’y
[40]
Brush Holder
[46]
Brush Terminal
[41]
Stator Ass’y
[40]
Noise Suppressor
[54]
Switch
[53]
Tube (D)
[55]
Cord
[61]
Cord Armor
[60]
Tapping Screw (W/Flange) D4 x 16
[58]
Cord Clip
[59]