32
PJLink command (continued)
Commands
Control Description
Parameter or Response
ERST ?
Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Lamp error; one of 0 to 2
3rd byte: Refers to Temptrature error; one of 0 to
2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected; 1 = Warning; 2 =
Error
LAMP ?
Lamp Status inquiry
1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on
INST ?
Input Source List inquiry 11 12 21 22 23 31 41 51 52
NAME ?
Projector Name inquiry
Responds with the name set in "PROJECTOR
NAME" of "NETWORK"
INF1 ?
Manufucturer's Name
inquiry
HITACHI
INF2 ?
Model Name inquiry
Your model name, "CP-X4021N", "CP-X5021N"
or "CP-WX4021N".
INFO ?
Other Information inquiry Responds with the factory information and so
on
CLSS ?
Class Information inquiry
1
NOTE
• The password used in PJLink
TM
is the same as the password set in
the Web Browser Co
n
trol. To use PJLink
TM
without authentication, do not set
any password in Web Browser Control.
• For speci
cations of PJLink
TM
, see the web site of the Japan Business
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/