![Hissmekano Viksam 3.0 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hissmekano/viksam-3-0/viksam-3-0_manual_2139294009.webp)
www.hissmekano.se
Manual Viksam 3.0 version 2
–
October 2022
8
4
Commissioning
4.1
Learning trip
For the door control to know the door's opening width, a learning trip is required. Set the power
switch to “Normal” and turn on the power. Then press the button as below to "learning trip". The
door will now at low speed open fully and then close and after a few cycles it will stay in the closed
position. NOTE. If it stays in the open position, the encoder may be incorrectly connected, see section
3.2. When the learning journey is finished, the push button must be set to the "normal" position and
then the door can be put into operation.
4.2
Manual mode
It is not a manual mode, but if you want to see if the door opens and closes as it should, you can set
the push buttons to the "2-wire" and "Normal" positions and jumper between screw terminals "9"
and "11" (open) / " 12” (close).
NOTE. Be sure to disconnect the cables that go to the elevator control before the jumper.