www.hissmekano.se
Manual Viksam 3.0 version 2
–
October 2022
6
3.3
Interface and settings
The connection of open and close signals takes place through two different options: 1-wire or 2-wire.
2-wire is recommended when these signals are available in the control system.
The desired option is set on the push button, see below.
Control of the door is done via the digital inputs on the screw terminal inputs "9
–
12". If the door
control is connected with a separate opening and closing signal, i.e. 2-wire communication, the
pushbutton on the left of the image above must be set to "2-wire". The door will then open when
closed between "9" and "11" and close when closed between "9" and "12". If there is no signal or if
both signals are active, the door will stay in its current position.
If the door control is connected to a common opening and closing signal, 1-wire communication, the
push button must be set to "1-wire" as above. The door will then close in the event of a short circuit
between "9" and "10" and open when the connection is broken.
The folding door closes when "12" is activated
and opens when "11" is activated.
The folding door closes when "10" is activated
and opens when it is deactivated
3.4
Pinch/crushing protection
Pinch protection in both opening and closing cycles and managed internally.
In case of blocking, the door will reverse and then make another opening attempt where the door
slows down to the position where the door was previously blocked. After a complete open/close
cycle, the door returns to normal operation again.