Hissmekano Viksam 3.0 Скачать руководство пользователя страница 11

 

 

 

www.hissmekano.se 

Manual Viksam 3.0 version 2 

 October 2022 

 

10 

 

6

 

Spare parts 

 
Door controller 

3710333 

Drive belt (per meter) 

3700007 

Tension roller incl. shoulder  3700006 
Fuse 

 

7070239 

Motor 

 

3710331 

Motor/tension roller angle  3710298 
Power supply unit 

3710332 

 

7

 

Maintainance  

7.1

 

Lubrication of tension roller 

Push the roller down so that a small gap appears and spray some spray grease into the gap that 
appears. Recommended to be performed at the time of service. 

 

7.2

 

Adjustment of belt 

If adjustment of the belt is required, see the instructions in chapter 3.5. 

Содержание Viksam 3.0

Страница 1: ...Viksam 3 0...

Страница 2: ...Voltage supply 5 3 2 Motor and encoder connection 5 3 3 Interface and settings 6 3 4 Pinch crushing protection 6 3 5 Relay contacts 7 3 6 Blocking 7 3 7 Door hanging 7 4 Commissioning 8 4 1 Learning...

Страница 3: ...rature 0 till 50 C Max voltage current for relays 230 VAC 10A Fuse 6 3A slow 5x20mm Inputs Open Signal Close signal Connections 12 x screw terminals for motor encoder signals Supply cable IEC C14 Rela...

Страница 4: ...ackside of the hanger rail Each angle needs 4x square nuts and 4x hexagonal screws Adjust the angles to approx 10mm from each pilaster Mount the idler pulley furthest into the track of the bracket to...

Страница 5: ...lley is pressed against the frame See the figure below This requires that the angle is correctly mounted on the rail and that the idler pulley has some space left in the track Belt tension adjustment...

Страница 6: ...ied with a quick connect IEC C14 cable for the power supply This is connected to 230 VAC and earth A fuse 2 5A slow is located in the connection housing 3 2 Motor and encoder connection The motor is d...

Страница 7: ...n 9 and 12 If there is no signal or if both signals are active the door will stay in its current position If the door control is connected to a common opening and closing signal 1 wire communication t...

Страница 8: ...e opening closing phase the door will always reverse but the signal can be taken from the relay contacts on the inside of the control After 3 attempts the control will wait for a new signal 3 7 Door h...

Страница 9: ...ay in the closed position NOTE If it stays in the open position the encoder may be incorrectly connected see section 3 2 When the learning journey is finished the push button must be set to the normal...

Страница 10: ...www hissmekano se Manual Viksam 3 0 version 2 October 2022 9 5 Troubleshooting...

Страница 11: ...9 Motor 3710331 Motor tension roller angle 3710298 Power supply unit 3710332 7 Maintainance 7 1 Lubrication of tension roller Push the roller down so that a small gap appears and spray some spray grea...

Отзывы: