Table 1 Outdoor Fault Code
60
Fault
code
Fault
d
escription
Possible
r
eason
s for
a
bnormality
How to
d
eal
w
ith
R
emarks
1
Outdoor ambient
temperature sensor
fault
1.The outdoor ambient temperature
sensor
is connected
loose
ly
;
2.The outdoor ambient temperature
sensor
fails to work
;
3.The sampling circuit
fails.
1.Reconnect the outdoor
ambient temperature sensor;
2.Replace the outdoor ambient
temperature sensor
components;
3.Replace the outdoor control
board components.
2
Outdoor coil
temperature sensor
fault
1.
The outdoor coil temperature
sensor
is connected loosely
;
2.
The outdoor coil temperature
sensor
fails to work
;
3.
The sampling circuit
fails.
1.Reconnect the outdoor coil
temperature sensor;
2.Replace the outdoor coil
temperature sensor
components;
3.Replace the outdoor control
board components.
3 The unit over-current
turn off fault
1.
Control board current sampling
circuit fail
s
;
2.
The current is over high because
the supply voltage is too low
;
3.
The compressor is blocked
;
4.
Overload in cooling mode
;
5.
Overload in heating mode
.
1. Replace the electrical control
board components;
2. Normally protection;
3. Replace the compressor;
4. Please see the Note 3;
5. Please see the Note 4.
4 EEprom Data error
1.
EE components fail
s
;
2.
EE components control circuit
fail
s
;
3.
EE components
are
insert
ed
incorrect
ly.
1.
2.
Replace the EE components;
Replace the outdoor control
board components;
3.Reassembl
e
the EE
components.
5
Cooling freezing
protection (the indoor
coil temperature is too
low) or heating
overload (indoor coil
temperature is too
high)
1.
2.
The indoor unit can not blow air
normally;
The room temperature is too low in
cooling mode or the room
temperature is too high in heating;
3.
The filter is dirty;
4.
The duct resistance is too high to
result in low air flow;
5.
The setting fan speed is too low;
6.
The indoor unit is not
installed
in
accordance with the installation
standards
,
and the
air inlet is too
close to the
air outlet .
1.
Check
whether
the indoor fan,
indoor
fan motor and
evaporator
work
normally;
2.
Normal protection;
3.
Clean the filter;
4.
Check the volume control
valve, duct length etc.;
5.
Set the speed with high speed;
6.
Reinstall the indoor unit
refer
ring
to
the user manual to
change the
distance between
the indoor
unit and the wall or
ceiling.
7
The communication
fault between the
indoor unit and
outdoor unit
1.
2.
The connection cable
is
connect
ed
improperly
between the indoor unit
and
outdoor unit;
The communication cable
is
connect
ed
loose
ly
;
3.
The communication cable
fails
;
4.
The indoor control board
fails
;
5.
The outdoor control board
fails
;
6.
Communication circuit fuse open;
7.
The specification of
communication cable is incorrect.
2.
3.
1.Reconnect the connection
cable refer
ring
to the wiring
diagram;
Reconnect the communication
cable;
Replace the communication
cable;
4.
Replace the indoor control
board;
5.
Replace the outdoor control
board;
6.
Check the communication
circuit, adjust the DIP switch
and the short-circuit fuse.
7.
Choose suitable
communication cable
refer
ring
to
the user manual
Содержание 2AMW-42U4RRA
Страница 10: ...1 GENERAL Type Capacity Btu h View 1 to 5 indoor units 42K 6 ...
Страница 15: ...3 OUTLINES AND DIMENSIONS 21K AMW3 24U4RFA Unit mm 11 ...
Страница 16: ...3 OUTLINES AND DIMENSIONS AMW3 24U4RAA Unit mm 414 380 12 ...
Страница 17: ...3 OUTLINES AND DIMENSIONS 27K Unit mm 414 380 13 ...
Страница 18: ...3 3 O OU UT TL LI IN NE ES S A AN ND D D DI IM ME EN NS SI IO ON NS S Unit mm 42K 14 ...
Страница 29: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 12K 14K 18K 21K 24K 25 ...
Страница 32: ...8 WIRING DIAGRAM Electric wiring diagram 1982504 D 21K AMW3 24U4RFA 28 ...
Страница 33: ...8 WIRING DIAGRAM AMW3 24U4RAA Electric wiring diagram 1957327 B 29 ...
Страница 34: ...8 WIRING DIAGRAM 27K 36K 30 ...
Страница 39: ...8 WIRING DIAGRAM Maintenance board Select switch signal to mainboard Communication signal to main board 35 ...
Страница 80: ...Product improvement specifications and appearance in this manual are subject to change without prior notice ...