If circuit breaker or fuse is often activated, stop the system and contact your service contractor.
●
Check that the ground wire is securely connected.
If the unit is not correctly grounded, it
will
lead
to
electric shock. Do not connect the ground wiring to gas piping, water piping, lightning
conductor
or ground wiring for telephone.
●
Before performing any brazing work, check to ensure that there is no flammable material around
w
hen using refrigerant
.
B
e sure to wear leather gloves to prevent cold injuries.
●
Protect the wires, electrical parts, etc. from rats or other small animals.
If not protected, rats may gnaw at unprotected parts
,
which may lead to
fire.
●
Fix the cables securely. External forces on the terminals could lead to a fire.
●
Install the air conditioner on a solid base that can support the unit weight. An inadequate base or
incomplete installation may cause injury in the event the unit falls off the base. Incomplete
connections or clamping may cause terminal overheating or fire.
●
Make sure that the outdoor unit is not covered with snow or ice, before operation.
●
Do not step or put any material on the product.
●
Do not put any foreign material on the unit or inside the unit.
●
It is recommended that the room be ventilated every 3 to 4 hours.
●
The air conditioner may not work properly under the following circumstances.
The power transformer provides the same power
with
the air conditioner. The electrical
equipment
is too close to the power supply of the air conditioner. With the sharp change of power
consumption and switching action, the power supply of the air conditioner will generate a large
induction surge voltage.
CHECKING PRODUCT RECEIVED
●
Upon receiving this product, inspect it for any shipping damage. Claims for damage, either apparent
or concealed, should be filed immediately with the shipping company.
●
Check the model number, electrical characteristics (power supply, voltage and frequency) and
accessories to determine if they are correct.
The standard utilization of the unit shall be explained in these instructions.
Therefore, the utilization of the unit other than those indicated in these instructions is not
recommended.
Please contact your local agent, as the occasion arises.
The figures in this manual are based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have selected.
Содержание 2AMW-42U4RRA
Страница 10: ...1 GENERAL Type Capacity Btu h View 1 to 5 indoor units 42K 6 ...
Страница 15: ...3 OUTLINES AND DIMENSIONS 21K AMW3 24U4RFA Unit mm 11 ...
Страница 16: ...3 OUTLINES AND DIMENSIONS AMW3 24U4RAA Unit mm 414 380 12 ...
Страница 17: ...3 OUTLINES AND DIMENSIONS 27K Unit mm 414 380 13 ...
Страница 18: ...3 3 O OU UT TL LI IN NE ES S A AN ND D D DI IM ME EN NS SI IO ON NS S Unit mm 42K 14 ...
Страница 29: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 12K 14K 18K 21K 24K 25 ...
Страница 32: ...8 WIRING DIAGRAM Electric wiring diagram 1982504 D 21K AMW3 24U4RFA 28 ...
Страница 33: ...8 WIRING DIAGRAM AMW3 24U4RAA Electric wiring diagram 1957327 B 29 ...
Страница 34: ...8 WIRING DIAGRAM 27K 36K 30 ...
Страница 39: ...8 WIRING DIAGRAM Maintenance board Select switch signal to mainboard Communication signal to main board 35 ...
Страница 80: ...Product improvement specifications and appearance in this manual are subject to change without prior notice ...