For the supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the protective conductor with the clamp.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires in the terminal block by tightening the terminal screws.
2.6.2
Supply voltage with the characteristic value KK
You will find information on the characteristic values here:
“Device name and product code” on page 21
You have the option of supplying the supply voltage redundantly, without
load distribution.
Both supply voltage inputs are uncoupled.
With a redundant supply, the supply voltage 1 (upper voltage input on the
device) has priority.
AC voltage
Rated voltage range AC:
110 V AC ... 230 V AC,
50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances:
88 V AC ... 265 V AC,
47 Hz ... 63 Hz
+/L
Outer conductor
-/N
Neutral conductor
Protective conductor
WARNING
ELECTRIC SHOCK
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
Table 11: Supply voltage with characteristic value K9: type and specification of the
supply voltage, pin assignment