2.6
Connecting the terminal blocks
Note:
The supply voltage is connected to the device casing through
protective elements exclusively.
2.6.1
Supply voltage with the characteristic value K9
You will find information on the characteristic values here:
“Device name and product code” on page 21
Figure 4: Supply voltage with the characteristic value K9: 3-pin terminal block with
screw locking
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 7.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for electric conductors, and do not touch the terminals.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range DC:
60 V DC ... 250 V DC
Voltage range DC incl.
maximum tolerances:
48 V DC ... 320 V DC
+/L
Plus terminal of the supply voltage
-/N
Minus terminal of the supply
voltage
Protective conductor
Table 11: Supply voltage with characteristic value K9: type and specification of the
supply voltage, pin assignment
N
L
Содержание RSPE30