Installation RSPE30/32/35/37
Release 16 04/2019
13
Control Drawing for RSPE devices according to Class
,
Division 2 Hazardous Locations
Rev.: 1
Document No.: 000182303DNR
Page 1/2
For Use in Hazardous Locations Class I Division 2 Groups A, B, C, D:
Only allowed for RSPE/RSPM model No´s. which are individually labeled
“FOR USE IN HAZARDOUS LOCATIONS”.
This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, and D OR non-hazardous locations only.
Nonincendive eld wiring circuits must be wired in accordance with the National Electrical Code
(NEC), NFPA 70, article 501.
WARNING – EXPLOSION HAZARD
Substitution of any components may impair suitability for hazardous locations or explosive
atmospheres.
WARNING – EXPLOSION HAZARD
Do not disconnect equipment unless power has been switched off or the area is known to be
known to be non-hazardous.