Set Learning Values (Teaching)
Measure the "tightening torque" and "working time" by using screws and materials actually used to set
the reference values for work. The two values recorded are the minimum and maximum, respectively.
Also, after teaching, it is possible to change the error tolerance of the learning values and the learned
values in the attached application or Excel file.
CAUTION
Teaching should be done under the same conditions as actual operation.
An error may occur in the measured value if the screw to be used, the materials to be fastened, the
attaching method of the screw, etc., are different from actual operation.
❶
Press and hold the teaching button.
Control Unit
◦
A buzzer sounds in about 2 seconds and the teaching mode is enabled.
◦
The teaching indicator is lit.
◦
L.NG indicator and H.NG indicator blinks.
❷
Using the screws and materials to be actually used, perform tightening more than 3 times.
◦
Every time after tightening is completed, a buzzer sounds once, and the measured value is recorded.
◦
The measured values of the third to tenth trials are recorded and the values after the eleventh trial
will overwrite the old values.
❸
Press and hold the teaching button.
◦
A buzzer sounds in about 2 seconds and the teaching mode ends.
◦
The teaching indicator, L.NG indicator and H.NG indicator turn off.
■
About Learning Values
◦
The learned values do not disappear even when the power is turned off.
◦
To reset the learned values, perform teaching again. The previous learned values will be deleted when
the teaching mode is enabled.
◦
After purchasing, please perform teaching with PG-01 for the first time. Otherwise, it is not possible to
set learning values with the attached application.