Symptoms
Cause
Solution
8. Troubleshooting
Caution Turn OFF the power switch before diagnosing any symptoms.
8-1
The device does
not operate even
after turning the
power switch ON
8-2
There is no front/rear
movement in the rail
8-3
Screws do not
move down
• There is no powe
r being supplied to the device
• A screw at the screw feeding point has not been
taken out within the set time
• There are too many screws in the panning area
• A foreign object (screw etc) has entered the device
• The AC adapter is faulty
• A screw is jammed in the gap
• There is no screw jammed, however there is no oscilla
-
tion
• Screws with a different rail specified thread have
been inserted
• The amount of screws in the panning area has de
-
creased
• Misaligned screws in the passing plate are not
swept up by the brushes
• Screws have become m
isaligned in the rail
• Check the power connection to the AC adapter
• Remove the screw at the screw feeding point
• Adjust the timer setting volume knob
• Ensure appropriate level of screws in the panning area
• Remove the foreign object
• Contact the store of purchase
• Remove the screw that is jammed in the gap
• Check the oscillation amplitude
Contact the store of purchase if the device does not operate even
after making adjustments
• Use screws with specified threads
• Remove any mixed screws
• Insert the appropriate amount of screws into the panning area
• Adjust the brushes
• Adjust the passing plate
• This can be resolved by inserting the appropriate amount of
screws into the panning area
• Replace the drive belt (replaceable part)
• Use the optional brushes (harder brushes)
• Remove any misaligned screws
Remove the misaligned screws using the method below, ensuring
not to damage the rail groove.
Remove the holding plate by moving it upwards, and adjust th
e
position of the holding plate
- 22 -