
6-1 Replacement and adjustment of brushes
If misaligned screws are no longer swept up by the tips of the brushes, the brushes should be replaced with new items. Brushes
with harder tips than the standard items are also available as an optional extra.
These brushes can be used to suit your requirements.
• Turn the power switch ON/OFF and position the brush as shown on the right
to remove the brush tips (Image 21).
(This positions the brush mounting screws in an easy to reach location)
• The brush tip mountings are as shown on the right.
• Assemble the brushes in the reverse order of disassembly.
• For adjustments, refer to “Making checks and adjustments before use”.
Brush part numbers
HSF-02107: HSF-10, HSF-12, HSF-14, HSF-17, HSF-20
HSF-22001-23: HSF-26, HSF-30
Image 21
Mounting screws
Hexagonal socket screw
M2.6 x 10
Spring washer M2.6
Plain washer M2.6
Brush bracket B
Brush
Brush bracket A
- 18 -