■
Alarms
52
/
52
17.2 Error list (operation errors)
Error
No.
Name
Description
Status
Cause
Solution
100
Screw
tightening
operation
error
Screw
tightening
operation
error
Emergency stop
button was pressed
Emergency stop button
was pressed
Check the device status
and perform error reset
Screw tightening time
was exceeded
The time of the operation
exceeded the time set for
the screw tightening cycle
Check the device status
and perform error reset
102
Torque
judgment NG
Torque
judgment NG
Torque judgment
result is NG
Detected a value outside
the upper or lower limit of
the range, in the screw
tightening torque
judgment
Check the device status
and perform error reset
103
I/O input NG
External I/O
CH No and
external I/O
PTN No entry
omission
The channel No. and
pattern No. from the
external I/O have not
been selected
Input error
Perform error reset, then
enter the external I/O
channel No. and pattern
No.
104
Angle
judgment NG
Screw
tightening
operation
error
Error in additional
tightening angle or
loosening angle
Occurs if the angle does
not reach the angle
specified when pattern 2,
3, or 4 is set
Specify the angle again
when pattern 2, 3, or 4 is
set
17.3 Error list (SVC errors)
Error
No.
Name
Description
Status
Cause
Solution
200
+ SVC
error
No.
SVC error
SVC error
Error occurred in SV-
NET controller.
The error No. is 200
+ the SVC error No.
Controller program error,
etc.
Refer to the user's manual
for the SV-NET controller.
Содержание DCD-40L
Страница 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Страница 27: ... Operation timing charts 27 52 Pattern 2 ...
Страница 28: ... Operation timing charts 28 52 Pattern 3 ...
Страница 29: ... Operation timing charts 29 52 Pattern 4 ...
Страница 36: ... I O 36 52 11 4 I O input timing charts Timing chart for normal operations when torque judgment is OK ...
Страница 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Страница 38: ... I O 38 52 Timing chart when emergency stop signal is input ...