■
Operation parameters
22
/
52
Trq 3
(Torque 3: N.m)
Torque for additional tightening
3.000
0.300
1.300
Cycle TM
(Cycle time: s)
Specified time for full set of operations of each pattern
30
5
100
Hold TM
(Holding time: ms)
Holding time after torque-up for full tightening and
additional tightening
* See Chapter 15 "Holding time"
150
50
500
Torque allowance
(Torque judgment
range: ±%)
Motor torque judgment range for full tightening and
additional tightening
5
1
99
Counter
Setting for number of times that normal motor torque value
is detected, for screw tightening judgment.
10
1
100
* The minimum value is 30° because the torque-down causes the bit to spring back when the servo turns OFF after full
tightening is complete.
Содержание DCD-40L
Страница 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Страница 27: ... Operation timing charts 27 52 Pattern 2 ...
Страница 28: ... Operation timing charts 28 52 Pattern 3 ...
Страница 29: ... Operation timing charts 29 52 Pattern 4 ...
Страница 36: ... I O 36 52 11 4 I O input timing charts Timing chart for normal operations when torque judgment is OK ...
Страница 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Страница 38: ... I O 38 52 Timing chart when emergency stop signal is input ...