Operation parameters
25
/
52
Pattern 3, Reverse torque –
Full
(Torque for pattern 3
loosening operation -
Negative percentage of full
tightening torque)
This setting specifies the torque for the reverse
rotation, as negative torque relative to the full
tightening torque, to prevent excessive
looseness in the screw when the loosening
operation in pattern 3 is performed.
The unit is -%.
0
0
100
Torque down filter setting
1st step
(Torque-down filter setting -
Step 1 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
2nd step
(Torque-down filter setting -
Step 2 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
3rd step
(Torque-down filter setting -
Step 3 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
Wait Time
(Torque-down filter setting -
Wait time)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The wait time
specifies the amount of time to wait before
applying each change to the torque limit setting.
The unit is msec. * See Chapter 16.
0
0
999
Содержание DCD-40L
Страница 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Страница 27: ... Operation timing charts 27 52 Pattern 2 ...
Страница 28: ... Operation timing charts 28 52 Pattern 3 ...
Страница 29: ... Operation timing charts 29 52 Pattern 4 ...
Страница 36: ... I O 36 52 11 4 I O input timing charts Timing chart for normal operations when torque judgment is OK ...
Страница 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Страница 38: ... I O 38 52 Timing chart when emergency stop signal is input ...