[Edit] screen
15
/
52
■ Screen display items (buttons)
Screen display
button
Description
Select the channel No. Touch the [▲] button to increase the number, and touch the [▼]
button to
decrease it.
A value from 1 to 8 can be selected.
Select the pattern No. Touch the [▲] button to increase the number, and touch the [▼]
button to
decrease it.
A value from 1 to 4 can be selected.
Load the saved parameters for the combination of channel No. and pattern No.
When loading is complete, the [Data loaded] message window is displayed.
Save the currently configured parameters for the combination of channel No. and pattern No.
If parameters have already been saved for the combination, the data is overwritten.
When saving is complete, the [Data saved] message window is displayed.
Open the screen for configuring special settings that apply to all operation patterns, and settings that
are specific to the motor.
Since the settings are normally configured by HIOS, a password is required in order to display the
screen.
[Next]/[Prev]
Display the next or previous page of the [Edit] screen.
Return to the main screen.
Содержание DCD-40L
Страница 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Страница 27: ... Operation timing charts 27 52 Pattern 2 ...
Страница 28: ... Operation timing charts 28 52 Pattern 3 ...
Страница 29: ... Operation timing charts 29 52 Pattern 4 ...
Страница 36: ... I O 36 52 11 4 I O input timing charts Timing chart for normal operations when torque judgment is OK ...
Страница 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...