System settings
44
/
52
13. System settings
On the touch panel VT3 system settings screen, you can change the password and set whether or not a sound is emitted
when buttons are touched.
In addition, the system settings screen can be used to monitor the device, by checking the total number of screw tightening
OK judgments.
■ Displaying the system settings screen
To display the system settings screen on the touch panel, first place a finger on the screen where there are no other buttons
for at least 3 seconds, then remove your finger for less than 1 second and touch the top right edge of the touch panel screen.
* For more information, refer to Chapter 9 "Special operations screen" in the "VT3_Hardware.pdf".
■ Checking the screw tightening OK judgment
count
You can check the total number of screw tightening OK judgments by viewing the MW07FE and MW07FF built-in touch panel
devices in [
デバイスモニタ
] (Device monitor) on the system settings screen.
MW07FE: The count increases by 1 for each 10,000 OK judgments. (Unit: 10,000 times)
MW07FF: The count increases by 1 for each OK judgment, and the count is reset to 0 when the count reaches 10,000. (Unit:
1 time)
* For more information, refer to Chapter 5 "System modes" in the "VT3_Hardware.pdf".
Note: When TP project data is transferred, all device values are reset (judgment counts are set to 0).
■
Checking the total number of screw tightening OK judgments
[Total No. of fastened Counter] (Total count monitor for screw tightening OK judgments - OK judgment counter)
■ You can check the total number o
f times that the screw tightening OK judgment has been counted.
Содержание DCD-40L
Страница 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Страница 27: ... Operation timing charts 27 52 Pattern 2 ...
Страница 28: ... Operation timing charts 28 52 Pattern 3 ...
Страница 29: ... Operation timing charts 29 52 Pattern 4 ...
Страница 36: ... I O 36 52 11 4 I O input timing charts Timing chart for normal operations when torque judgment is OK ...
Страница 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Страница 38: ... I O 38 52 Timing chart when emergency stop signal is input ...