Installation - Spray Control 31
INLINE SYSTEMS
In an Inline System the Flowmeter and Servo
Control Valve MUST be after all agitation and
Bypass lines and inline with all the flow to the
booms.
THE FLOWMETER MUST ONLY MEASURE
THE FLOW TO THE BOOMS. THEREFORE, IT
MUST BE AFTER ANY RETURN LINES.
THE FLOWMETER MUST MEASURE THE
FLOW TO THE ENTIRE BOOM. THEREFORE,
IT MUST BE BEFORE THE BOOM CONTROL
VALVES.
The Bypass or Agitation line should be a mini-
mum of 1-inch and contain a manual control
valve. This valve is required to make overall
sprayer adjustments.
An optional Bypass line may be installed to in-
crease Bypass for high capacity pumps. This
line MUST have a manual control valve.
TANK
FLOWMETER
VALVE
HM860
FILTER
SERVO
VALVE
OPTIONAL
VALVE
MANUAL
VALVE
OPTIONAL
BY-PASS
PUMP
MANUAL
MANUAL
LINES WITH
VALVE
BOOM VALVES
TO BOOMS
DWG. NO. 2733
A filter is recommended before the flowmeter.
Recommended mounting for the HM860
Flowmeter is vertical with the arrow pointing up.
The Servo Valve should be mounted horizontally
with the cover up to prevent dirt and water from
accumulating inside the cover.
All lines up to the Boom Control Valves should
be a minimum of 1-inch diameter. Smaller than 1-
inch diameter lines may restrict the flow and limit
the speed in which you may be able to spray.
NOTE: AT 55 PSI INPUT PRESSURE, THE
SERVO VALVE MAY LEAK UP TO 2.5 GAL-
LONS PER MINUTE. THERE IS NO CONTROL-
LING BELOW THIS RATE. FOR VERY LOW
FLOW RATES A “BYPASS INSTALLATION” IS
RECOMMENDED.