18 Calibration
STEP
DISPLAYED
ACTION YOU TAKE
8
VALVE RESPONSE 5
Set value for valve response in automatic 1 to 9.
Use numeric keys or the or key.
Larger number = faster response.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
9
FLOW METER
CALIBRATE 72.0
This number must match the pulses per gallon number on
the decal on the flowmeter.
Use numeric keys to set value or
Press key to increase number.
Press key to decrease number.
IMPORTANT: Make sure you enter the pulses per gallon
calibration number.
17.0 PULSES/LB PULSES/Gal 72.0
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
10
DIST. CALIBRATION
FACTOR 2.00
Use numeric keys to set value or
Press key to increase calibration factor.
Press key to decrease calibration factor.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
If you have not performed the distance calibration procedures as outlined on page 16. You must do
so to determine what the distance calibration factor is. By performing the distance calibration on
page 16 the 8605 will automatically enter the distance calibration factor for step 10. If using a Hiniker
GPS Speed Sensor enter 2.00 as the Calibration number.
11
BOOM #1 WIDTH
240 INCHES
Use numeric keys to set value or
Press key to increase the total width in inches for boom #1.
Press key to decrease the total width in inches for boom #1.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
12
BOOM #2 WIDTH
240 INCHES
Use numeric keys to set value or
Press key to increase the total width in inches for boom #2.
Press key to decrease the total width in inches for boom #2.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
13
BOOM #3 WIDTH
240 INCHES
Use numeric keys to set value or
Press key to increase the total width in inches for boom #3.
Press key to decrease the total width in inches for boom #3.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.