![Hiniker 8605 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/hiniker/8605/8605_operators-manual_2136895010.webp)
8 Operation
KEYPAD
The keypad is used for operator entry during Cali-
bration and operation. The number keys are used
for Calibration. The audible alarm is used with the
keypad to indicate data entry into the controller.
Each key press of the keypad results in a single
“beep” to signify acknowledgement of the key
press.
Keypad operation is described below.
TOTAL VOLUME
Press TOTAL VOL key to view the total gallons or
pounds of actual nitrogen applied. Total Volume
accumulates only when the console is in RUN. To-
tal Volume will not accumulate in HOLD.
Total Volume may be cleared to zero by depress-
ing the TOTAL VOL key for three seconds.
A solid tone will warn that Total Volume is about to
be cleared, release the key to abort. Total volume
is cleared at the end of the tone.
TOTAL AREA
Press TOTAL AREA key to view total acres.
Total Acres accumulate only when the console is
in RUN. Total Acres will not accumulate when in
HOLD.
The 8605 will automatically correct for the change
in implement width while calculating area when
any of the boom switches are turned off or on.
NUMERIC KEYS
1
2
ERROR
MENU
ENTER
O
5
O
RATE
3
4
HOLD
5
RUN
AREA
FIELD
FIELD
VOL.
AREA
TOTAL
TIME
DATE
SPEED
DIST.
TOTAL
VOL
HINIKER
I
O
8605
RATE
RATE
MANUAL
2
1
6
7
8
0
1
2
3
4
9
VPM
DWG. NO. 3136A
Total Area may be cleared to zero by depressing
the TOTAL AREA key for three seconds.
A solid tone will warn that Total Area is about to
be cleared, release the key to abort. Total Area is
cleared at the end of the tone.
FIELD VOLUME
Pressing the FIELD VOL key displays the current
Field and Chemical numbers along with the Date/
Time Stamp. After three seconds Gallons or actual
Nitrogen applied for the current selection will be
displayed.
Field volume may be cleared to zero by depress-
ing the FIELD VOL key for three seconds. This will
clear the Field Volume data accumulated to date
for the currently selected field and chemical num-
bers.
A solid tone will warn that volume is about to be
cleared, release the key to abort. Field Volume is
cleared at the end of the tone.
Clearing the Field Volume also signals that this is
the start of a new Field/Chemical application re-
cord. The record will be stamped with the current
date and time to indicate when the new application
record was started. If you are in NH3 mode, the
new record will be tagged as an NH3 record. The
print out of NH3 application records show the field
volume as pounds of actual nitrogen rather than as
gallons of liquid.
Field Volume accumulates only when the controller
is in Run. Field Volume will not accumulate in HOLD.