Calibration 17
CALIBRATION PROCEDURES - SPRAY APPLICATIONS
STEP
DISPLAYED
ACTION YOU TAKE
1
CALIBRATION MODE
Select Calibration Mode from the Main Menu.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
2
FIELD NUMBER
Use numeric keys to enter field number. (1-99) or
Press key to increase number.
Press key to decrease number.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
3
CHEMICAL NUMBER
Use numeric keys to enter chemical number. (1-16) or
Press key to increase chemical number.
Press key to decrease chemical number
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
4
APPLICATION:
1. SPRAY
Press , keys to make selection.
2. NH
3
Select 1. Spray
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
5
SERVO LOCATION:
Press , keys to make selection.
1. INLINE
Select Inline if the servo valve is installed inline with the
flow to the booms.
2. BYPASS
Select Bypass if the servo valve is installed in a return or
agitation line back to the tank or pump inlet.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
6
APPLY RATE 1
10.0 GAL/ACRE
Use numeric keys to set value or
Press key to increase the gallon per acre for Rate 1.
Press key to decrease the gallon per acre for Rate 1.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
7
APPLY RATE 2
20.0 GAL/ACRE
Use numeric keys to set desired value or
Press key to increase gallon per acre for rate 2.
Press key to decrease gallon per acre for rate 2.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.