![Hiniker 8605 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/hiniker/8605/8605_operators-manual_2136895032.webp)
TITLE
30 Installation - Spray Control
INTRODUCTION
This section describes how to plumb a sprayer
for use with the Hiniker 8605 controller.
There are two basic configurations. The Inline
system and the Bypass system. The Inline sys-
tem is when the Servo Valve controls the flow
to the nozzles. The Bypass system configuration
has the Servo Valve controlling the return flow to
the tank or pump.
The Bypass system is better suited for flow rates
under 5 gallons per minute, where the Inline sys-
tem is better suited for higher flow rates. The
vast majority of flow rates are between 5 and 30
gallons per minute. For these rates it is recom-
mended to use the Inline system.
To determine required gallons per minute with
your sprayer, use this formula.
GPM =
GPA x MPH x Width (ft.)
495
NOTE: THIS SECTION ONLY DESCRIBES
SYSTEMS USING THE HM860 FLOWMETER
AND THE NEW STEPPER MOTOR SERVO
VALVE. THE 8605 CONTROLLER CANNOT
BE USED WITH OTHER SERVO VALVES.
TANK
PUMP
PRESSURE
REGULATOR
FILTER
FLOWMETER
SERVO
VALVE
INLINE
SYSTEM
BYPASS
SYSTEM
CONTROL
V
A
LVES
LEF
T
BOOM
MIDDLE BOO
M
RIGHT
BOOM
DWG. NO. 1279
INSTALLATION – SPRAY CONTROL