![Hilti SI 100 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/hilti/si-100/si-100_operating-instructions-manual_2136047005.webp)
2
Technical data
Rated voltage:
120 V
Rated current:
6.0 A
Mains frequency:
60 Hz
No-load speed:
0–2200 /min.
Impact speed:
Max. 2600 impacts/min.
Clockwise / counter-clockwise rotation:
Performance identical
Chuck:
1
/
2
″
square pin with retaining pin
Screwdriver weight without supply cord:
5 lbs
Max. tightening torque:
100 Nm / 74 ft. lbs
Double insulation, class II
Right of technical modifications reserved
Anchor products / suitable setting tools
Anchor products
HUS-H
3
/
8
HRD-U10/HRD-S10/
Setting tools
HUS-H
1
/
2
HRD-U14
Socket wrench insert S-NSD
9
/
16
1
/
2
L
●
Socket wrench insert S-NSD
1
/
2
1
/
2
L
●
Socket wrench insert S-NSD
9
/
16
1
/
2
●
Socket wrench insert S-NSD
1
/
2
1
/
2
●
Socket wrench insert S-NSD 13
1
/
2
●
Socket wrench insert S-NSD 17
1
/
2
●
Bit holder S-BHU 50
1
/
2
×
1
/
4
●
●
Bit S-B-TX 40T
●
Bit S-B-TX 40
●
Bit S-B-TX 50
●
Extensions S-V125
1
/
2
×
1
/
2
●
●
Anchor products other than the above-mentioned may not be driven in with or tightened by the SI 100 impact
screwdriver.
Description
The SI100 impact screwdriver is an electric tool.
Recommended screwdriver usage:
– Driving Hilti screw anchors of the HUS-H
3
/
8
size and
larger into concrete of C20 to C50 grade and removing
them in accordance with the manufacturer’s recom-
mendations. The HUS 7.5 size may not be screwed
in.
– Driving screws into Hilti HRD framing anchors in
accordance with the manufacturer’s recommendations.
Extension Cords.
Make sure your extension cord is in
good condition. When using an extension cord, be
sure to use one heavy enough to carry the current your
product will draw. An undersized cord will cause a
drop in line voltage resulting in loss of power and over-
heating. The following table shows the correct size to
use depending on cord length and nameplate ampere
rating. If in doubt, use the next heavier gage. The
smaller the gage number, the heavler the cord.
Extension Cord Table
Volts
Total Length of Cord in Feet
120 V
0–25
26– 50
51–100 101–150
240 V
0–50
51–100
101–200 201–300
Ampere Rating
AWG
More Than Not More Than
0
6
18
16
16
14
6
10
18
16
14
12
10
12
16
16
14
12
12
16
14
12
Not recommanded
Printed: 07.07.2013 | Doc-Nr: PUB / 5070690 / 000 / 00
Содержание SI 100
Страница 2: ...1 2 3 4 5 6 Printed 07 07 2013 Doc Nr PUB 5070690 000 00...
Страница 17: ...14 Printed 07 07 2013 Doc Nr PUB 5070690 000 00...
Страница 25: ...22 Printed 07 07 2013 Doc Nr PUB 5070690 000 00...
Страница 33: ...Printed 07 07 2013 Doc Nr PUB 5070690 000 00...
Страница 34: ...Printed 07 07 2013 Doc Nr PUB 5070690 000 00...
Страница 35: ...Printed 07 07 2013 Doc Nr PUB 5070690 000 00...