4 Technical data

Right of technical changes reserved.

PR 300-HV2S

Receiving range (diameter)

Typical distance with PRA 300: 2…600 m (6.56…

1,968.5 ft)

Range of remote control (circle diameter)

Typical distance with PRA 300, In the open field, with-

out external influences: 0…240 m (0…787.4 ft)

Accuracy

1

at 10 m (33 ft): ± 0.5 mm (0.02 in)

Plumb beam

Continuous, perpendicular to the plane of rotation

Laser class

Class 2, 620-690 nm; < 1 mW (EN 60825-1:2007 / IEC

60825-1:2007); Maximum power < 4.85 mW at ≧ 300

r.p.m.

Speed of rotation

600/min, 1,000/min (during the automatic alignment

procedure)

Inclination range

With the tool already inclined: ≤ 25%

Self-leveling range

±16° X-axis, ±10° Y-axis

Power source

7.2V/ 4.5 Ah Li‑ion battery

Battery life

Tempe25°C (+77 °F), Li‑ion battery: ≥ 25 h

Operating temperature range

-20…+50°C (−4…+122 °F)

Storage temperature range (dry)

-25…+60°C (−13…+140 °F)

Protection class

IP 66 (in accordance with IEC 60529); Not in “charging

during operation” mode

Tripod thread

⁵⁄₈" x 18

Weight (incl. PRA 84)

2.5 kg (5.51 lb)

Drop test height

2

1.5 m (4.92 ft)

1 Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated

otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810G).

2 The drop test was carried out from a tripod, dropping onto flat concrete under standard ambient conditions (MIL-STD-810G).

PRA 300

Detection range (area diameter)

With the PR 300-HV2S (typical): 2…600 m (6.56…

1,968.5 ft)

Signal tone generator

3 volume levels plus mute setting

Liquid-crystal display

On both sides

Indicator range, distance from zero

± 52 mm (± 2 in)

Laser plane display range

± 1.0 mm (0.04 in)

Length of the detection area

120 mm (4.72")

Casing top edge center indicator

75 mm (2.95")

Marking notches

On both sides

Time without detection before automatic power off

15 min

Weight (including batteries)

0.25 kg (0.55 lb)

Power source

2 AA batteries

Battery life

Tempe20°C (+68 °F): Approx. 40 h (depending

on the quality of the alkaline batteries used)

Operating temperature range

-20…+50°C (−4…+122 °F)

Storage temperature range

-25…+60°C (−13…+140 °F)

1 The drop test was carried out using the PRA 83 receiver holder, dropped onto flat concrete under standard ambient conditions

(MIL-STD-810G).

en

7

Printed: 28.08.2015 | Doc-Nr: PUB / 5244524 / 000 / 00

Содержание PR 300-HV2S

Страница 1: ... 2108731 2108731 PR 300 HV2S Operating instructions en Mode d emploi fr Manual de instrucciones es Manual de instruções pt Printed 28 08 2015 Doc Nr PUB 5244524 000 00 ...

Страница 2: ... 1 Printed 28 08 2015 Doc Nr PUB 5244524 000 00 ...

Страница 3: ...2 3 4 5 6 ...

Страница 4: ...7 8 9 10 ...

Страница 5: ...11 12 13 14 15 16 ...

Страница 6: ...17 18 ...

Страница 7: ...19 20 ...

Страница 8: ...21 ...

Страница 9: ...RA 84 Li Ion battery Battery compartment 2 PRA 84 Li Ion battery Battery compartment Catch Charging the battery in the tool 3 PUA 81 AC adapter Charging socket Charging the battery externally not in the tool 4 PUA 81 AC adapter PUA 82 motor vehicle power adapter Charging activity LED Rotating laser control panel 5 On off button Auto leveling LED LED arrow for electronic inclination alignment Manua...

Страница 10: ...on the type identification plate on the tool Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department Type Generation 01 Serial no 2 Safety instructions 2 1 Basic information concerning safety In addition to the information relevant to safety given in each of the sections of these operating instructions...

Страница 11: ...hock if your body is earthed or grounded y Do not expose the supply cord to heat oil or sharp edges z Never operate the AC adapter when it is dirty or wet Dust especially dust from conductive ma terials or dampness adhering to the surface of the AC adapter may under unfavorable condi tions lead to electric shock Dirty or dusty tools should thus be checked at a Hilti Service Center at regular inter...

Страница 12: ...directly into sources of bright light In the event of direct eye contact with the laser beam close your eyes and move your head out of the path of the laser beam Do not direct the laser beam toward persons 3 Description 3 1 Use of the product as directed The Hilti PR 300 HV2S is a rotating laser tool with a visible rotating laser beam and a reference beam set at 90 to the main beam The rotating la...

Страница 13: ... operation due to vibration or an impact all LEDs begin to blink and the laser switches off the head stops rotating 3 8 Automatic cut out The laser does not switch on and all LEDs blink if the tool is set up outside its self leveling range 16 X axis 10 Y axis or if movement is blocked mechanically The tool can be set up on a tripod with a 5 8 thread or stood directly on some other steady surface f...

Страница 14: ...h orange LED arrows light constantly The tool is correctly aligned with the PRA 300 The orange LED arrow on the left lights The tool must be rotated in a clockwise direction The orange LED arrow on the right lights The tool must be rotated in a counter clockwise direction All LEDs All LEDs blink The tool has been bumped or is indicat ing a fault 3 12 Charge state of the Li ion battery while the to...

Страница 15: ...1 5 m 4 92 ft 1 Influences such as particularly high temperature fluctuations dampness shock dropping etc can affect accuracy Unless stated otherwise the tool was adjusted or calibrated under standard ambient conditions MIL STD 810G 2 The drop test was carried out from a tripod dropping onto flat concrete under standard ambient conditions MIL STD 810G PRA 300 Detection range area diameter With the...

Страница 16: ... 51 lb 5 Before use NOTE The tool may be powered only by a Hilti PRA 84 or PRA 84G battery 5 1 Inserting the battery 2 1 Slide the battery into the tool 2 Turn the catch in a clockwise direction until the locked symbol appears 5 2 Removing the battery 8 1 Turn the catch in a counter clockwise direction until the unlocked symbol appears 2 Remove the battery from the tool 5 3 Charging the battery 5 ...

Страница 17: ...ies in the laser receiver NOTE Check to ensure correct polarity when insert ing the batteries 3 Close the battery compartment cover 5 8 Pairing The rotating laser and the remote control laser receiver are already paired when supplied Additional laser re ceivers of the same type or PRA 90 automatic tripods are not ready for use until they have been paired The rotating laser and these accessories mu...

Страница 18: ...After switching on the tool begins to level itself automatically 6 4 Working with the PRA 300 laser receiver remote control unit The PRA 300 is a combined laser receiver and remote control unit The remote control makes working with the rotating laser more convenient and is required in order to make use of certain functions The laser beam is indicated by visual and audible signals 6 4 1 Using the P...

Страница 19: ...laser receiver on by pressing the on off button 5 Hold the laser receiver with the detection area directly in the plane of the rotating laser beam 6 Position the laser receiver so that the distance display shows 0 7 Use the measuring tape to measure the desired distance 6 5 Menu options on the PRA 300 laser receiver remote control unit 1 The Menu key may be pressed at any time during operation The...

Страница 20: ...s These are marked on the casing of the tool and can be set as follows 1 In the menu select the system settings and confirm your selection by pressing the key 2 Select the Activate deactivate beam shields function and confirm your selection by pressing the key 3 Use the arrow keys to navigate to the correct quadrant 4 Activate deactivate the desired quadrants by pressing the OK key 5 Confirm this ...

Страница 21: ...otating laser is switched on and a wireless connection has been established Pressing the Back key takes you back to the main menu 6 5 4 1 Deactivating the shock warning function 1 Switch the rotating laser on see 6 3 2 Press the Deactivate shock warning key The shock warning deactivation LED lights constantly indicating that the function has been deactivated If the shock warning function is deacti...

Страница 22: ...ect the Wireless connection option 4 Confirm your selection by pressing the key 5 Choose the correct wireless connection and activate this by pressing the key 6 5 5 Information When this menu item is selected you have the following options Software version The software version of the tool receiver and PRA 90 can be viewed here Date of last calibration The date of the last calibration can be viewed...

Страница 23: ... required height A constant signal tone is emitted while this is taking place As soon as the laser beam strikes the detection area of the laser receiver the beam moves to the position of the marking notch reference plane After the position has been reached and the rotating laser has leveled itself a signal tone with a duration of 5 seconds indicates that the process is complete The Automatic align...

Страница 24: ...reached i e the marking notch is found a signal tone with a duration of 5 seconds indicates that the process is complete The laser receiver switches automatically to surveillance mode and checks at regular intervals whether the laser plane has shifted If it is found to have shifted the laser plane will be readjusted to the original marking notch as far as possible If the marking plane is outside t...

Страница 25: ...tered with the laser receiver remote control unit The display on the laser receiver shows the angle of inclination If a slope adapter or an already inclined tripod is also used inclinations of up to 25 can be achieved You can set the X and Y inclinations at the same time or for just one of the two axes 1 Use the arrow keys or to select soft key X and then confirm your choice by pressing 2 Then use...

Страница 26: ...ection of the search can be changed by pressing the Automatic alignment key once As soon as the laser beam strikes the detection area of the laser receiver the beam is fixed at the position of the marking notch reference plane Once the position is reached i e the marking notch is found a signal tone with a duration of five seconds indicates that the process is complete The Automatic alignment symb...

Страница 27: ...t to NiCd or NiMH batteries NOTE For best results batteries should be stored fully charged in a cool dry place Storing the battery in places subject to high ambient temperatures e g at a window has an adverse effect on battery life and increases the rate of self discharge NOTE Batteries lose capacity due to aging and overstressing They can then no longer be fully charged You may continue to work w...

Страница 28: ... point point 1 on the wall 4 Pivot the tool clockwise through 90 about its own axis In doing so ensure that the height of the tool does not change 5 Use the laser receiver to catch the laser beam and mark a second point point 2 on the wall 6 Repeat steps 4 and 5 twice and mark points 3 and 4 on the wall with the aid of the laser receiver When this is done carefully the vertical distance between th...

Страница 29: ...pty The receiver s battery is almost empty Charge the battery soon Rotating laser battery symbol The rotating laser s bat tery is almost empty The rotating laser s bat tery is almost empty Charge the battery soon Tripod battery symbol The tripod s battery is al most empty The tripod s battery is al most empty Charge the battery soon Autoalignment The Autoalignment pro cess was canceled The receive...

Страница 30: ...device pursuant to part 15 of the FCC rules These limits are designed to pro vide reasonable protection against harmful interference in a residential installation This equipment generates uses and may radiate radio frequency energy Accord ingly if not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that ...

Страница 31: ...2108731 2108731 Hilti Corporation LI 9494 Schaan Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan Pos 3 20150803 Printed 28 08 2015 Doc Nr PUB 5244524 000 00 ...

Отзывы: