4 Technical data
Right of technical changes reserved.
PR 300-HV2S
Receiving range (diameter)
Typical distance with PRA 300: 2…600 m (6.56…
1,968.5 ft)
Range of remote control (circle diameter)
Typical distance with PRA 300, In the open field, with-
out external influences: 0…240 m (0…787.4 ft)
Accuracy
1
at 10 m (33 ft): ± 0.5 mm (0.02 in)
Plumb beam
Continuous, perpendicular to the plane of rotation
Laser class
Class 2, 620-690 nm; < 1 mW (EN 60825-1:2007 / IEC
60825-1:2007); Maximum power < 4.85 mW at ≧ 300
r.p.m.
Speed of rotation
600/min, 1,000/min (during the automatic alignment
procedure)
Inclination range
With the tool already inclined: ≤ 25%
Self-leveling range
±16° X-axis, ±10° Y-axis
Power source
7.2V/ 4.5 Ah Li‑ion battery
Battery life
Tempe25°C (+77 °F), Li‑ion battery: ≥ 25 h
Operating temperature range
-20…+50°C (−4…+122 °F)
Storage temperature range (dry)
-25…+60°C (−13…+140 °F)
Protection class
IP 66 (in accordance with IEC 60529); Not in “charging
during operation” mode
Tripod thread
⁵⁄₈" x 18
Weight (incl. PRA 84)
2.5 kg (5.51 lb)
Drop test height
2
1.5 m (4.92 ft)
1 Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810G).
2 The drop test was carried out from a tripod, dropping onto flat concrete under standard ambient conditions (MIL-STD-810G).
PRA 300
Detection range (area diameter)
With the PR 300-HV2S (typical): 2…600 m (6.56…
1,968.5 ft)
Signal tone generator
3 volume levels plus mute setting
Liquid-crystal display
On both sides
Indicator range, distance from zero
± 52 mm (± 2 in)
Laser plane display range
± 1.0 mm (0.04 in)
Length of the detection area
120 mm (4.72")
Casing top edge center indicator
75 mm (2.95")
Marking notches
On both sides
Time without detection before automatic power off
15 min
Weight (including batteries)
0.25 kg (0.55 lb)
Power source
2 AA batteries
Battery life
Tempe20°C (+68 °F): Approx. 40 h (depending
on the quality of the alkaline batteries used)
Operating temperature range
-20…+50°C (−4…+122 °F)
Storage temperature range
-25…+60°C (−13…+140 °F)
1 The drop test was carried out using the PRA 83 receiver holder, dropped onto flat concrete under standard ambient conditions
(MIL-STD-810G).
en
7
Printed: 28.08.2015 | Doc-Nr: PUB / 5244524 / 000 / 00
Содержание PR 300-HV2S
Страница 2: ... 1 Printed 28 08 2015 Doc Nr PUB 5244524 000 00 ...
Страница 3: ...2 3 4 5 6 ...
Страница 4: ...7 8 9 10 ...
Страница 5: ...11 12 13 14 15 16 ...
Страница 6: ...17 18 ...
Страница 7: ...19 20 ...
Страница 8: ...21 ...