5. Activate / deactivate sleep mode by pressing the OK key
.
NOTE
All settings remain saved.
6.5.4 Tool settings
Shock warning sensitivity
High vibration, low sensitivity to shock
Medium
Low
Inclined plane mode units
Percent
Degrees
Thousandths
Units
Millimeters
Inches
Wireless connection
On
Off
Settings that affect the rotating laser only become effective when the rotating laser is switched on and a wireless
connection has been established. Pressing the “Back” key
takes you back to the main menu.
6.5.4.1 Deactivating the shock warning function
1. Switch the rotating laser on (see 6.3).
2. Press the “Deactivate shock warning” key .
The shock warning deactivation LED lights constantly, indicating that the function has been deactivated.
If the shock warning function is deactivated, the tool no longer reacts to shock (i.e. when bumped or shaken).
3. To return to standard operating mode, switch the tool off and then switch it back on again.