Evaluation Board
60/108
Switch S600-B - UART interface
State of S600-B
UART interface mode
OFF
Enable UART over DSub
ON
Enable UART over RS-232 (with external module NXHX-
RS232 available as accessory)
Table 23: Switch S600-B - Modes of using the UART interface
See figure below.
SPM Switch (S600-C)
Switch S600-C allows switching between different modes of using the SPM
interface, which are explained in the following table:
Switch S600-C - SPM interface
State of S600-C
SPM interface mode
OFF
SPM over the integrated FTDI chip (USB interface)
ON
SPM over the pin header X600 (
Table 24: Switch S600-C - Modes of using the SPM interface
See figure below.
User-defined LEDs (S600-D)
The ADCs and the user-defined LEDs of the NRPEB H90-RE cannot be
used simultaneously. Switch S600-D decides which feature to use. Set
switches according to the subsequent table.
Switch S600-D - ADCs vs. User LEDs
State of S600-D
ADCs
User LEDs
OFF
ADCs enabled
User LEDs
disabled
ON
ADCs disabled
User LEDs
enabled
Table 25: Switch S600-D – Switching between ADCs and User LEDs
netRAPID 90 | Design guide
DOC190601DG01EN | Revision 1 (Draft 10) | English | 2019-09 | Preliminary | Public
© Hilscher 2019