Configuring gateway
46/98
SmartWire-DT Gateway | EU5C-SWD-ETHERCAT
DOC140901UM01EN | Revision 1 | English | 2015-03 | Released | Public
© Hilscher 2015
8.2.2.2
Step-by-step instructions
1. Copy device description files into TwinCAT directory.
In the Windows Explorer, open the directory where the device
description files are stored. On the product DVD, this is the
EDS\EU5C-
SWD-ETHERCAT\Vx.x.x.x
directory.
Copy the device description files.
Note:
You need the
Phoenix_EU5C-SWD-
ETHERCAT_Modules_XXXXXXXX.xml
and
Woehner_EU5C-SWD-
ETHERCAT_Modules_XXXXXXXX.xml
files only if the Smart-Wire-DT
network includes partner devices by Phoenix or Wöhner.
Copy the files to the
TwinCAT\Io\EtherCAT
directory of the TwinCAT
installation on your configuration PC.
The device description files of the gateway and the SmartWire devices
are now available in the TwinCAT System Manager.
2. Start TwinCAT.
In the Windows start menu, select
All
Programs
>
TwinCAT
System
>
TwinCAT
System Manager
.
The TwinCAT System Manager opens:
Figure 14: TwinCAT start screen
If you already dispose of a project into which you want to integrate the
gateway, open the corresponding project file.
If you haven’t created a project yet, you first have to configure the Ethernet
adapter of your PC as EtherCAT
®
master device.