User Manual of Area Scan GigE Camera
53
Trigger_in1
Sensor
exposure
Intergration
1
Intergration
2
Trigger delay
Trigger_in2
Trigger delay
Frame time
Frame time
Frame1
Readout
Frame2
Readout
Figure 3-13
External Trigger Mode
3.4
Image Acquisition and Transmission
Image acquisition mode is divided into internal trigger mode and external trigger
mode. Internal trigger mode includes continuous acquisition mode and single frame
acquisition mode. External trigger mode includes software trigger mode and hardware
external trigger mode.
Select On or Off in Trigger Mode to select either internal trigger mode or external
trigger mode. (Off refers to the internal trigger mode and On refers to the external
trigger mode.)
3.4.1
Internal Trigger Mode
The Camera can output one image or several images continuously in the internal
trigger mode.
Click Acquisition Control in the attribute list. Select Acquisition Mode and you will
see elements of Continuous and SingleFrame. Continuous refers to outputting images