HIKVISION DS-PK00 series Скачать руководство пользователя страница 30

Network Security Control Panel User Manual 

24 

 

Demonstration: 

E.g.,  the  user  password  is 
1234. 

LCD Display 

Press  the  user  password:  [1] 
[2] [3] [4]. 

xxxx*1

 

Press [*] to enter the working 
mode. 

Press  [1]  to  cancel  the  alarm 
under the arming status. 

Press  [#]  to  confirm  the 
operation. 

If 

the 

operation 

is 

successful, 

Operation Succeeded

 

If  the  operation  is  failed,

Operation Failed

 

Canceling Alarm under the Disarming Status 
Command 1: [User Password

+

*

+

1

+

#

 

Содержание DS-PK00 series

Страница 1: ...Network Security Control Panel User Manual i UD07466B Network Security Control Panel User Manual...

Страница 2: ...jurisdictions Other trademarks and logos mentioned below are the properties of their respective owners Legal Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH IT...

Страница 3: ...a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t...

Страница 4: ...signated collection point For more information see www recyclethis info Industry Canada ICES 003 Compliance This device meets the CAN ICES 3 B NMB 3 B standards requirements This device complies with...

Страница 5: ...le de 20 cm entre le radiateur et votre corps Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss The precaution m...

Страница 6: ...gh electromagnetic radiating environment Do not aim the lens at the strong light such as sun or incandescent lamp The strong light can cause fatal damage to the product The sensor may be burned out by...

Страница 7: ...arming _________________________________ 15 2 3 3 Zone Bypass Operation ____________________________________________ 16 2 3 4 Instant Arming ___________________________________________________ 19 2 3...

Страница 8: ..._____________________________________________ 45 2 3 26 Auto Registration _________________________________________________ 46 2 3 27 Signal Strength Query ____________________________________________...

Страница 9: ...es and so on 1 2 System Definition 1 2 1 Partition Definition Partition is an independent area divided from the security control panel Partitions are independent control system and can provide arming...

Страница 10: ...by arming and disarming operation or be bypassed When the zone detects alarm events the sound and light alarming prompt will be triggered on the keyboard The siren output will be triggered when the si...

Страница 11: ...zone type is generally used in the smoke detector Perimeter Zone Instant Zone When the system is armed the detectors of this zone will be in alert condition The zone will be immediately triggered whe...

Страница 12: ...s to a programmable relay output of the security control panel and a connection between the security control panel and the follow up output device By linking the relay the security control panel can s...

Страница 13: ...ors and no alarm will be trigger by controller Bypass You can bypass any zone to turn off the protection of it when some exception occurs while other zones can work normally Bypass Recovering You can...

Страница 14: ...refer to the user manual based on the corresponded model for other appearance No Description 1 Keypad 2 LED LCD Screen 3 Control Panel 4 Indicator Bar Control Panel Button Description Panic Button Pr...

Страница 15: ...start up and enter the properly status of working 2 2 2 Alarm Keypad Start up The LED keypad will make continuously prompt tones if the keypad does not receive the registration respond from the contro...

Страница 16: ...rking Status Indicator Normal OFF Fault Solid Red Alarm Flicking Red Bypass Solid Green Zone Indicator under Engineering Mode The corresponding zone indicator light will turn orange when operating No...

Страница 17: ...working properly is shown below Global Keypad SYS1D SYS2R SYS3A SYS4R SYS5R SYS6R SYS7R SYS8R The system status description is shown below System Status Description SYS1D Partition1 Disarmed SYS2R Par...

Страница 18: ...dule Exception Programming System Status abnormal Display Demonstration Global Keypad SYS1D SYS2R SYS3A SYS4R SYS5R SYS6R SYS7R SYS8R Partition Keypad The system exception display of the partition key...

Страница 19: ...rk1 Sending Report Network1 Sending report succeeded 2 2 3 Buzzer Description No Sound Prompt Description 1 One Beep Pressing keys prompt The command is timed out or the command is too long 2 Two Beep...

Страница 20: ...r does not enter the partition The object of keypad operation is the whole system of the control panel Partition Keypad Mode In this mode the user enters the partition The object of keypad operation i...

Страница 21: ...9 Press to enter the working mode Press the device initialization command 8 and 9 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation...

Страница 22: ...successful Operation Succeeded If the operation is failed Operation Failed Disarming The current status is status of arming Press the user password 1 2 3 4 xxxx Press and the status of arming will be...

Страница 23: ...the zone No 0 3 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed Multi Zones Bypass Operation Function Through the multi z...

Страница 24: ...is required to be entered once only xxxx Bypass 03 Press the bypass key to bypass zone No 3 Press the zone No 0 3 Press to confirm the operation Press the bypass key to bypass zone No 4 Bypass 04 Pres...

Страница 25: ...delay is 0s Command User password 7 Demonstration E g the user password is 1234 LCD Display Press the user password 1 2 3 4 xxxx 7 Press to enter the working mode Press 7 and the control panel enters...

Страница 26: ...Press 4 and the control panel enters the stay arming status Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed 2 3 6 Force Ar...

Страница 27: ...Press the bypass key Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed Force Instant Arming Function After the operation is...

Страница 28: ...orce instant arming status Press the bypass key Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed Force Stay Arming Function...

Страница 29: ...the force stay arming status Press the bypass key Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed 2 3 7 Canceling Keypad A...

Страница 30: ...e user password 1 2 3 4 xxxx 1 Press to enter the working mode Press 1 to cancel the alarm under the arming status Press to confirm the operation If the operation is successful Operation Succeeded If...

Страница 31: ...s 1234 LCD Display Press the user password 1 2 3 4 xxxx 1 Press to enter the working mode Press 1 to cancel the alarm under the disarming status Press to confirm the operation If the operation is succ...

Страница 32: ...rming and disarming is the same After the operation is completed the arming status of the control panel will be changed the status of arming will be exchanged into disarming and vice versa Command Use...

Страница 33: ...on E g the user password is 1234 and the alarm output channel No is 001 LCD Display Press the user password 1 2 3 4 xxxx 85001 Press to enter the working mode Enable the alarm output by pressing 8 5 P...

Страница 34: ...Disable the alarm output by pressing 8 6 Press the alarm output channel No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation...

Страница 35: ...the user password is 1234 LCD Display Press the user password 1 2 3 4 xxxx 41 Press to enter the working mode Enable group bypass by pressing 4 1 Press to confirm the operation If the operation is suc...

Страница 36: ...e operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed Group bypass operation and group bypass recovery operation are available to all group bypass...

Страница 37: ...ter code is 1111 the user No Is 001 and the new user password is 5678 LCD Display Enter Password Changing Progress Master Code 0 Press the master code 1 1 1 1 xxxx 0 Change Password via Master Code En...

Страница 38: ...etween Control Panel and Remote Control Function You can match the codes of the remote control with ones of the control panel via the keypad 1 Enter the code matching mode Command User Password 9 1 Re...

Страница 39: ...the remote control No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed 2 Press any key of the keypad and the code is...

Страница 40: ...king mode Enter the mode for deleting code matched remote control by pressing 9 0 Press the remote control No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If...

Страница 41: ...deleting all code matched remote controls by pressing 9 2 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Failed 2 3 15Controlli...

Страница 42: ...ect to enter the project mode Press 1 0 to the mode for entering the user s card No Press the user No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If the ope...

Страница 43: ...ct mode Enter the mode for deleting appointed matched card by pressing 1 1 Press the user No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is...

Страница 44: ...mode for deleting all matched cards by pressing 1 5 Press the user No 0 0 1 Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed Operation Faile...

Страница 45: ...Press to confirm the operation If the operation is successful Operation Succeeded Programming If the operation is failed Operation Failed Exiting Programming Mode Command 2 3 17Prompt Operation Enabl...

Страница 46: ...ss to enter the working mode 52015 Enter the LCD backlight configuration mode by pressing 5 2 Pressing the backlight on duration 0 1 5 Note 0 1 5 means 15 seconds Press to confirm the operation If the...

Страница 47: ...imum volume The larger the number the louder the volume is You need to touch the keypad first to enable the adjusting function 2 3 20Language Switch Chinese English Function You can switch the languag...

Страница 48: ...nder the status of disarming and non fault of the zone The system will do auto arming in the zone testing mode without reporting any CID log The siren will start warning after the alarm is triggered a...

Страница 49: ...r password is 1234 LCD Display Press the user password 1 2 3 4 xxxx 61 Press to enter the working mode Relay test report manually by pressing 6 1 Press to confirm the operation If the operation is suc...

Страница 50: ...uploading mode LCD Display Press the user password 1 2 3 4 xxxxProject 901 Press the project key Project Press the control panel debugging command 9 0 Press the uploading mode n Note Different values...

Страница 51: ...e master code is 1234 LCD Display Press the master code 1 2 3 4 xxxx 68 Press to enter the working mode Press 6 8 to do the control panel soft recovery operation Press to confirm the operation If the...

Страница 52: ...to enter the working mode Press 8 2 to enter the auto searching mode of the global keypad Press to confirm the operation If the operation is successful Operation Succeeded If the operation is failed...

Страница 53: ...on If the operation is successful Operation Succeeded If the operation is failed Operation Failed 2 3 27Signal Strength Query Function You can view the 3G 4G and SUB 1G wireless signal strength via th...

Страница 54: ...stem automatically displays the interface of first priority 3 The switch between interfaces of same priority there are two ways to switch display interface of the sensor alarm to sensor off line displ...

Страница 55: ...ing OSD notices after each program command is over When 5 alert sound of error is heard and the screen displays Operation Failed there is error in program command setting and the user need to reset co...

Страница 56: ...indicator under Status Mode No Description No Description 1 AC Power off 5 Keypad Off line 2 Battery Low Voltage 6 Network Cable Off line 3 Control Panel Tamper proof On 7 No SIM Card 4 ADSL Cable Off...

Страница 57: ...removing alarm memory as shown below 1 Under disarming mode Press 1 or Password 1 2 Under arming mode Press Password 1 Q How to input hexadecimal number A Input hexadecimal number with button and numb...

Страница 58: ...28 2 1 3 4 5 DIP ON 29 2 1 3 4 5 DIP ON 30 2 1 3 4 5 DIP ON 31 Q Why is it needed to input E at the end of keypad configured phone number A Control panel can process phone number with 31 characters In...

Страница 59: ...ample when a criminal forces the user to disarm the alarm user can input the control panel duress code to disarm the system and upload the alarm information to the center automatically and off the cri...

Страница 60: ...g contents Q How to do the hardware initialization A Control panel hardware initialization only initializes operator password 012345 and main operator password 1234 main operator permission is arm dis...

Страница 61: ...ommunication Protocols of the remote alarm center in Remote Configuration Others Network Center Configuration 2 If the user communicates via dialing Configure parameters such as phone number receiver...

Страница 62: ...h alarm center by programming with keypad For detailed operations please refer to program command 611 634 Q Why cannot it upload report and control after WIFI is enabled A The follow situations may le...

Страница 63: ......

Отзывы: