Network Security Control Panel User Manual
5
not be affected by arming and disarming operation or be bypassed.
When the zone detects alarm events, the sound and light alarming
prompt will be triggered on the keyboard. The siren output will be
triggered when the siren is linked, meanwhile the generated event
report will be uploaded to the center receiver (the uploaded report is
different with the report of 24-Hr Audible Alarm Zone), and the zone
alarm status can be checked on the client. Generally, it is used to define
a zone with emergency button, or a zone used to monitor devices, such
as water detector or temperature sensor.
Fire Alarm Zone
The detectors of this zone are in 24 hours’ alert condition, which will
not be affected by arming and disarming operation or be bypassed.
When the zone detects alarm events, the sound and light alarming
prompt will be triggered on the keyboard. The siren output will be
triggered when the siren is linked, meanwhile the generated event
report will be uploaded to the center receiver (the uploaded report is
different with the report of 24-Hr Audible Alarm Zone), and the zone
alarm status can be checked on the client. This zone type is generally
used in the smoke detector.
Perimeter Zone/Instant Zone
When the system is armed, the detectors of this zone will be in alert
condition. The zone will be immediately triggered when it detects
alarm event, and the system will alarm instantly without any delay time.
When the system is disarmed, if the zone hasn’t recovered, a zone
alarm recovered report will be automatically reported to the center
receiver, and the zone turns to fault status. This zone type can be
assigned to all the detectors, especially the detectors that used to
protect doors and windows.
Entering/Exiting Delayed Zone
The system will provide exiting delay after performing the arming
operation. The zone will not alert during exiting delay and the detectors
of this zone will be in alert condition at the end of exiting delay. When
the system is in arm away or arm stay, it will provide enter delay when
the zone detects alarm event. Users must disarm the system by the end
of enter delay, if not, the zone alarm will be triggered. When the
system is in arm instant, the alarm will occur instantly after the zone
detects alarm event, and the system will not provide enter delay. Both
the exiting delay and enter delay can be programmable set. This zone
type is mainly used in entrance/exit route (e.g. front door/main
entrance), which is a key route to operate keyboard for users.