Network Security Control Panel User Manual
19
Operation Failed
Multi-zones bypass/bypass recovery should be conducted in 15 seconds. For example,
bypass operations of the zone No. 04 and zone No. 05 should be completed in 15
seconds in the above demonstration.
2.3.4
Instant Arming
Function: The control panel can be set into the instant arming status via the keypad. The
instant arming means that the exiting delay is 0s.
Command: [User password
]
+
[
*
]
+
[
7
]
+
[
#
]
Demonstration:
E.g., the user password is
1234.
LCD Display
Press the user password:
[1] [2] [3] [4].
xxxx*7
Press [*] to enter the
working mode.
Press [7], and the control
panel enters the instant
arming status.
Press [#] to confirm the
operation.
If the operation is successful,
Operation Succeeded
If the operation is failed,
Operation Failed
2.3.5
Stay Arming
Function: After the operation is completed, the partition will change the status of disarming
(current status) into arming immediately. The bypass supported zone of the partition will do
auto-bypass simultaneously.
Command: [User Password
]
+
[
*
]
+
[
4
]
+
[
#
]