Non-Visible Panic Alarm Station Configuration Guide
27
Figure 3-31 Audio Exception Detection Configuration Page
2. According to actual needs, select and check Enable Sudden Increase of Sound Intensity, Enable
Sudden Decrease of Sound Intensity. And set the parameters.
Note
Sensitivity(50) and Sound Intensity Thresholds(50) can be set from 1 to 100 and default to 50.
3. Click the drop-down box of Arming Schedule and set the arming schedule for audio exception
detection.
Note
There are three schedules.
●
The schedule template (not editable) that comes with the system, such as all-day template,
weekday template and event template.
●
Editable schedule template01 to template08. For detailed edit method, see Set System
Schedule.
●
Custom schedule. For detailed edit method, see Set Custom Schedule.
4. Check Trigger Alarm Output, select and check the alarm output signal that is linked when the
audio exception is detected.
5. Click Save.
Result
During the configured arming schedule, the audio anomaly event is detected according to the