Note
• Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the
keyfob will select only one of them to pair.
• For details about DIP switch value and meaning, see DIP Switch .
6. Optional: Go to System → User → Keyfob User on the remote control page of the client
software to delete the keyfob.
6.3 Initialize Device
Steps
1. Remove the JP11 jumper cap on the access control board.
Figure 6-1 Initialization Jumper Cap
2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep.
3. When the beep stopped, plug the jumper cap back.
4. Disconnect the power and power on the device again.
Caution
The initialization of the device will restore all the parameters to the default setting and all the
device events are deleted.
Note
Make sure no persons are in the lane when powering on the device.