background image

DS-K3B801SX Series Swing Barrier

Quick Start Guide

Содержание DS-K3B801SX Series

Страница 1: ...DS K3B801SX Series Swing Barrier Quick Start Guide ...

Страница 2: ...HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY OR OTHERWISE IN CONNECTION WITH THE USE OF THE PRODUCT EVEN IF HIKVISION HAS BEEN ADVIS...

Страница 3: ...evice with facial recognition features biometrics data is stored in your device with encryption method for fingerprint device only fingerprint template will be saved which is impossible to reconstruct a fingerprint image As data controller you are advised to collect store process and transfer data in accordance with the applicable data protection laws and regulations including without limitation c...

Страница 4: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radi...

Страница 5: ...lection points For more information see www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling retur...

Страница 6: ...wer source during servicing Keep body parts away from motors Disconnect the power source during servicing To prevent possible hearing damage do not listen at high volume levels for long periods All the electronic operation should be strictly compliance with the electrical safety regulations fire prevention regulations and other related regulations in your local region Do not connect several device...

Страница 7: ...combustible surface only Install the equipment according to the instructions in this manual To prevent injury this equipment must be securely attached to the floor wall in accordance with the installation instructions Stainless steel may be corroded in some circumstances You need to clean and care the device by using the stainless steel cleaner It is suggested to clean the device every month Do no...

Страница 8: ...tructions provided by the battery manufacturer Biometric recognition products are not 100 applicable to anti spoofing environments If you require a higher security level use multiple authentication modes Do not stay in the lane when the device is rebooting RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS SUITABLE FOR MOUNTING ON ...

Страница 9: ...r DS K3B801SX L Left Pedestal DS K3B801SX M Middle Pedestal DS K3B801SX R Right Pedestal Scan the QR code to get User Manual of Swing Barrier Note that mobile data charges may apply if Wi Fi is unavailable DS K3B801SX Series Swing Barrier Quick Start Guide viii ...

Страница 10: ...over 21 Chapter 5 General Wiring 24 5 1 Components Introduction 24 5 2 Wiring Electric Supply 26 5 3 Wire Interconnecting Cable 27 5 4 Wire Network Switch 28 5 5 Face Recognition Terminal Power Supply Wiring 29 5 6 Terminal Description 30 5 6 1 Main Control Board Terminal Description 30 5 6 2 Sub Control Board Terminal Description 31 5 6 3 Access Control Board Terminal Description 32 5 6 4 Access ...

Страница 11: ...arm Relay Output Mode NO NC 46 Chapter 7 Activation 48 7 1 Activate via SADP 48 7 2 Activate Device via Client Software 49 Appendix A Tips for Scanning Fingerprint 51 Appendix B DIP Switch 53 B 1 DIP Switch Description 53 B 2 DIP Switch Corresponded Functions 53 Appendix C Event and Alarm Type 56 Appendix D Table of Audio Index Related Content 57 Appendix E Error Code Description 58 Appendix F Com...

Страница 12: ...ttractions stadiums construction sites residences etc 1 2 Main Features 32 bit high speed processor TCP IP network communication The communication data is specially encrypted to relieve the concern of privacy leak Permissions validation and anti tailgating Remaining open closed mode selectable Bidirectional Entering Exiting lane The barrier opening and closing speed can be configured according to ...

Страница 13: ...ent Online offline operation LED indicates the entrance exit and light bar indicates passing status Barrier remains open when powered down Fire alarm passing When the fire alarm is triggered the barrier will be open automatically for emergency evacuation Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing dur...

Страница 14: ...pedestal 2 Draw other parallel lines for installing the other pedestals Note The distance between the nearest two line is L 100 mm L represents the lane width 3 Slotting on the installation surface and dig installation holes according to the hole position diagram Figure 2 1 Hole Position Diagram DS K3B801SX Series Swing Barrier Quick Start Guide 3 ...

Страница 15: ...ry both of the AC power cord and the low voltage cable at the entrance the two cables should be in separated conduits to avoid interference If more peripherals are required to connect you should increase the conduit diameter or bury another conduit for the external cables The external AC power cord should be double insulated The network cable must be CAT5e or the network cable has better performan...

Страница 16: ...ameter of the low voltage conduit is larger than 30 mm If you want to bury both of the AC power cord and the low voltage cable at the entrance the two cables should be in separated conduits to avoid interference If more peripherals are required to connect you should increase the conduit diameter or bury another conduit for the external cables The external AC power cord should be double insulated T...

Страница 17: ...and screws You should prepare the following tools to disassemble the pedestal 1 Pedestal Key supplied 2 Allen Wrench 2 5 mm 3 Allen Wrench 3 mm 4 Allen Wrench 4 mm Steps 1 Use the pedestal key to open the front and back components Figure 3 1 Lock Position 2 Use the Allen wretch 4 mm to loosen the 2 screws M5 25 at the top of the device DS K3B801SX Series Swing Barrier Quick Start Guide 6 ...

Страница 18: ...long the arrow direction carefully Figure 3 3 Remove Components 4 Loosen the wing bolt M4 10 at the front and back of the pedestal and remove the front and back base covers along the arrow direction DS K3B801SX Series Swing Barrier Quick Start Guide 7 ...

Страница 19: ...e expansion screws to secure the device on the installation surface 5 Remove the motor bottom cover 1 Pull or push the barrier to the closed position 2 Use the Allen wretch 2 5 mm to loosen the 4 screws M4 8 on the motor bottom cover DS K3B801SX Series Swing Barrier Quick Start Guide 8 ...

Страница 20: ...Figure 3 6 M4 8 Screw 3 Pull or push the barrier to the open position and remove the motor bottom cover DS K3B801SX Series Swing Barrier Quick Start Guide 9 ...

Страница 21: ...stal you should dissemble two motor bottom covers 6 Use the Allen wretch 4 mm to loosen the 2 screws M5 12 at the front or back of the pedestal base and remove the side base cover slowly Figure 3 8 Remove Side Base Cover DS K3B801SX Series Swing Barrier Quick Start Guide 10 ...

Страница 22: ...s 3 2 Install Pedestals Before You Start Prepare for the installation tools check the device and the accessories and clear the installation base Steps Note The device should be installed on the concrete surface or other non flammable surfaces The dimension is as follows Figure 3 10 Dimension 1 Prepare for the installation tools check the components and prepare for the installation base DS K3B801SX...

Страница 23: ...ponded positions Note Make sure the installation holes on the pedestals and the base are aligned with each other 4 Secure the pedestals with expansion bolts Note Do not immerse the pedestal in the water In special circumstances the immersed height should be no more than 150 mm The installation footprint is as follows Figure 3 11 Installation Footprint DS K3B801SX Series Swing Barrier Quick Start G...

Страница 24: ...5 After installation assemble the components and screws back to the pedestal in reverse order except for protective sheets DS K3B801SX Series Swing Barrier Quick Start Guide 13 ...

Страница 25: ...prepare the following tools to disassemble the pedestal 1 Pedestal Key supplied 2 Allen Wrench 2 5 mm 3 Allen Wrench 3 mm 4 Allen Wrench 4 mm 4 1 Disassemble Front and Back Components After disassembling the front and back components you can maintain the front and back parts of the pedestal Steps 1 Use the pedestal key to open the front and back components DS K3B801SX Series Swing Barrier Quick St...

Страница 26: ...Figure 4 1 Lock Position 2 Use the Allen wretch 4 mm to loosen the 2 screws M5 25 at the top of the device DS K3B801SX Series Swing Barrier Quick Start Guide 15 ...

Страница 27: ...Figure 4 2 M5 25 Screws Position 3 Remove the components along the arrow direction carefully Figure 4 3 Remove Components DS K3B801SX Series Swing Barrier Quick Start Guide 16 ...

Страница 28: ...er position control board Steps 1 Pull or push the barrier to the closed position 2 Use the Allen wretch 2 5 mm to loosen the 4 screws M4 8 on the motor bottom cover Figure 4 4 M4 8 Screws Position 3 Pull or push the barrier to the open position and remove the motor bottom cover DS K3B801SX Series Swing Barrier Quick Start Guide 17 ...

Страница 29: ...ould dissemble two motor bottom covers 4 3 Disassemble Side Base Cover After disassembling the side base cover you can maintain the IR sending receiving board Steps 1 Use the pedestal key to open the front and back components DS K3B801SX Series Swing Barrier Quick Start Guide 18 ...

Страница 30: ...Figure 4 6 Lock Position 2 Use the Allen wretch 4 mm to loosen the 2 screws M5 25 at the top of the device DS K3B801SX Series Swing Barrier Quick Start Guide 19 ...

Страница 31: ...s along the arrow direction carefully Figure 4 8 Remove Components 4 Use the Allen wretch 4 mm to loosen the 2 screws M5 12 at the front or back of the pedestal base and remove the side base cover slowly DS K3B801SX Series Swing Barrier Quick Start Guide 20 ...

Страница 32: ...op of the pedestal the IR sending receiving board and the IR adaptor for instance Steps 1 Use the Allen wretch 2 5 mm to loosen the 4 captive panel screws at the top of the pedestal Figure 4 10 Loosen Captive Panel Screw 2 Move the front and back top covers along the arrow 1 s direction for about 3 cm and move them upwards to remove the front and back top covers DS K3B801SX Series Swing Barrier Qu...

Страница 33: ...e key to open and remove the front and back components and cut off the fingerprint modules power 4 Use the Allen wrench 2 5 mm to loosen the 2 captive panel screws displayed in the picture below Figure 4 12 Top Captive Panel Screws 5 Remove the top cover along the arrow s direction DS K3B801SX Series Swing Barrier Quick Start Guide 22 ...

Страница 34: ...Figure 4 13 Remove Top Cover DS K3B801SX Series Swing Barrier Quick Start Guide 23 ...

Страница 35: ...ting cables And the turnstile supports wiring the AC electric supply for the whole system s power supply Note The voltage fluctuation of the electric supply is between 100 VAC and 220 VAC 50 to 60 Hz The picture displayed below describes each component s position on the turnstile Note The diagram is for reference only DS K3B801SX Series Swing Barrier Quick Start Guide 24 ...

Страница 36: ...Figure 5 1 Components Diagram The picture displayed below describes the IR sending receiving module and their corresponding number on the pedestal DS K3B801SX Series Swing Barrier Quick Start Guide 25 ...

Страница 37: ...ceiving modules The IR modules on the left side of the middle pedestal are the IR receiving modules while the IR modules on the right side of the middle pedestal are the IR sending modules 5 2 Wiring Electric Supply Wire electric supply with the switch in the pedestal Terminal L and terminal N are on the switch while terminal PE should connect to a ground wire yellow and green wire DS K3B801SX Ser...

Страница 38: ...e wired reversely Do not wire the input and output terminal reversely To avoid people injury and device damage when testing the ground resistance of the equipotential points should not be larger than 2 Ω 5 3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication The picture displayed below describes the ca...

Страница 39: ...ructions below to connect the interconnecting cable Figure 5 4 Connect Interconnecting Cable 5 4 Wire Network Switch Connect the network cable and the network switch Steps 1 Open the side cover of the pedestal DS K3B801SX Series Swing Barrier Quick Start Guide 28 ...

Страница 40: ... switch s power interface 3 Connect the network cable with the network switch 5 5 Face Recognition Terminal Power Supply Wiring You should wire the power supply terminal on the 12 V power supply component if you connect the turnstile to the face recognition terminal The terminal s position is shown as follows DS K3B801SX Series Swing Barrier Quick Start Guide 29 ...

Страница 41: ...ol Board Terminal Description The main lane control board contains power supply interface supercapacitor interface brake interface motor drive interface light board interface motor encoder interface door open position detection interface debug port lane communication interface interconnecting interface and DIP switch reserved The picture displayed below is the main control board diagram DS K3B801S...

Страница 42: ...r interface brake interface motor drive interface light board interface motor encoder interface door open position detection interface debug port lane communication interface and interconnecting interface The picture displayed below is the sub control board diagram Figure 5 8 Sub Control Board DS K3B801SX Series Swing Barrier Quick Start Guide 31 ...

Страница 43: ...ut ERR Indicator of Card Reader Control Output Valid Card Output BZ Card Reader Buzzer Control Output W1 Wiegand Head Read Data Input Data1 W0 Wiegand Head Read Data Input Data0 GND Grounding Wiegand Card Reader 2 OK Indicator of Card Reader Control Output Invalid Card Output ERR Indicator of Card Reader Control Output Valid Card Output BZ Card Reader Buzzer Control Output W1 Wiegand Head Read Dat...

Страница 44: ...2 G Connect to Card Reader RS232 RS 232 G Connect to Card Reader RS232 GND Grounding RS 232 H Connect to Card Reader RS232 RS 232 H Connect to Card Reader RS232 Power Input 24 V 24 VDC Power Input GND Grounding Event Input C1 Event Alarm Input 4 GND Grounding C2 Fire Input C3 Event Alarm Input 2 GND Grounding C4 Event Alarm Input 1 Exit Button B2 Door 2 Signal Input GND Grounding B1 Door 1 Signal ...

Страница 45: ...ed together with the card recycler Normal users should present card on Card Reader 4 while visitors should present card on Card Reader 3 The Wiegand card reader 1 and 2 refer to the entering and exiting card reader respectively The alarm output supports relay output For any requirements the door lock can control the door barrier status of the third party D1 controls the barrier opening for entranc...

Страница 46: ...485 communication mode and the RS 232 communication mode By default it is in RS 485 communication mode UART6 Jumper Cap Use the jumper cap to switch the serial port communication mode with the sub lane controller You can switch between the RS 232 communication mode and the RS 485 communication mode By default it is in RS 232 communication mode UART5 Jumper Cap Use the jumper cap to switch the seri...

Страница 47: ...ove which has a fixed RS 232 communication mode to communicate with the main lane controller It contains no jumper cap and cannot change the communication mode UART7 UART8 Reserved serial port The serial port has a fixed RS 232 communication mode It contains no jumper cap and cannot change the communication mode which can connect with a QR code scanner The reserved interface positions in the turns...

Страница 48: ...the wiring of RS 485 card reader as an example For details about text screen see Configuring Screen Parameters in User Manual of iVMS 4200 AC Client Software 5 6 6 RS 232 Wiring Note There are three RS 232 interfaces UART4 UART7 and UART8 UART7 and UART8 can connect QR code scanner and card recycler while UART4 can connect QR code scanner card recycler and face recognition terminal DS K3B801SX Ser...

Страница 49: ...DS K3B801SX Series Swing Barrier Quick Start Guide 38 ...

Страница 50: ...oard The lane control board can control the barrier status If possible the device can connect with a third party lane control board to control the third party barriers Interface D1 controls barrier opening for entrance while interface D2 controls barrier opening for exit Note Use the jumper cap to switch the relay status For details see Barrier Control Relay Output Mode DS K3B801SX Series Swing Ba...

Страница 51: ...Entering Wiring Exiting Wiring DS K3B801SX Series Swing Barrier Quick Start Guide 40 ...

Страница 52: ...5 6 9 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap see Alarm Relay Output Mode NO NC DS K3B801SX Series Swing Barrier Quick Start Guide 41 ...

Страница 53: ...exit free entrance and prohibited exit prohibited bi direction prohibited entrance and free exit Memory Mode By default the memory mode is enabled When multiple cards are presented and authenticated it allows multiple persons passing through the lane When it counts the passing people number is equal to the card presented times or no person passing through the lane after the last person passing the...

Страница 54: ...y Before You Start Ask our technique supports or sales and purchase the keyfob Steps Note Up to 32 keyfobs can be added to the turnstile 1 Power off the turnstile 2 Set the No 4 switch of the DIP Switch on the access control board to the ON side 3 Power on the turnstile and it will enter the keyfob pairing mode 4 Hold the Close button for more than 10 seconds Or pair turnstile and keyfob in the cl...

Страница 55: ...eps 1 Remove the JP11 jumper cap on the access control board Figure 6 1 Initialization Jumper Cap 2 Disconnect the power and reboot the device The device buzzer buzzes a long beep 3 When the beep stopped plug the jumper cap back 4 Disconnect the power and power on the device again Caution The initialization of the device will restore all the parameters to the default setting and all the device eve...

Страница 56: ...lack part is the jumper cap The serial port is in RS 485 communication mode Figure 6 2 Jumper Cap Status of RS 485 Interface If the Jumper cap s position is like the picture displayed below The black part is the jumper cap The serial port is in RS 232 communication mode Figure 6 3 Jumper Cap Status of RS 232 Interface DS K3B801SX Series Swing Barrier Quick Start Guide 45 ...

Страница 57: ... cap s position of barrier opening for entrance NO is as below The jumper cap s position of barrier opening for exit NO is as below The jumper cap s position of barrier closing for entrance NC is as below The jumper cap s position of barrier closing for exit NC is as below 6 5 2 Alarm Relay Output Mode NO NC Alarm Relay Output Mode NO DS K3B801SX Series Swing Barrier Quick Start Guide 46 ...

Страница 58: ...Alarm Relay Output Mode NC DS K3B801SX Series Swing Barrier Quick Start Guide 47 ...

Страница 59: ... within the same subnet The following steps show how to activate a device and modify its IP address For batch activation and IP addresses modification refer to User Manual of SADP for details Steps 1 Run the SADP software and search the online devices 2 Find and select your device in online device list 3 Input new password admin password and confirm the password Caution STRONG PASSWORD RECOMMENDED...

Страница 60: ...rly Steps Note This function should be supported by the device 1 Enter the Device Management page 2 Click on the right of Device Management and select Device 3 Click Online Device to show the online device area The searched online devices are displayed in the list 4 Check the device status shown on Security Level column and select an inactive device 5 Click Activate to open the Activation dialog 6...

Страница 61: ...recommend you change your password regularly especially in the high security system changing the password monthly or weekly can better protect your product Proper configuration of all passwords and other security settings is the responsibility of the installer and or end user 7 Click OK to activate the device DS K3B801SX Series Swing Barrier Quick Start Guide 50 ...

Страница 62: ...horizontally The center of your scanned finger should align with the scanner center Incorrect Scanning The figures of scanning fingerprint displayed below are incorrect Environment The scanner should avoid direct sun light high temperature humid conditions and rain When it is dry the scanner may not recognize your fingerprint successfully You can blow your finger and scan again DS K3B801SX Series ...

Страница 63: ...rd to scan your fingerprint we recommend you to use other authentication methods If you have injuries on the scanned finger the scanner may not recognize You can change another finger and try again DS K3B801SX Series Swing Barrier Quick Start Guide 52 ...

Страница 64: ...ow its binary value is 00001100 and its decimal value is 12 B 2 DIP Switch Corresponded Functions Note After setting the DIP switch you should reboot the device or the function cannot take effect The 8 bit DIP switch corresponded functions on the access control board are as follows Bit Device Mode Function Decimal Value DIP Switch Address Diagram 1 to 2 Work Mode Normal Mode 0 Study Mode 1 Test Mo...

Страница 65: ...ng Mode 0 Enable Keyfob Paring Mode 1 5 to 8 Passing Mode Controlled Bi direction 0 Controlled Entrance and Prohibit Exit 1 Controlled Entrance and Free Exit 2 Free Bi direction 3 Free Entrance and Controlled Exit 4 Free Entrance and Prohibit Exit 5 Prohibited Bi direction 6 DS K3B801SX Series Swing Barrier Quick Start Guide 54 ...

Страница 66: ...Bit Device Mode Function Decimal Value DIP Switch Address Diagram Prohibit Entrance and Controlled Exit 7 Prohibit Entrance and Free Exit 8 DS K3B801SX Series Swing Barrier Quick Start Guide 55 ...

Страница 67: ...se Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible Free Passing Authentication Failed Visual Barrier Obstructed None DS K3B801SX Series Swing Barrier Quick Start Guide 56 ...

Страница 68: ...3 Card No and fingerprint mismatch 4 Climbing over the barrier 5 Reverse passing 6 Passing timeout 7 Intrusion 8 Force accessing 9 Tailgating 10 No permissions 11 Authentication time out 12 Authentication failed 13 Expired card 14 Staying out of time DS K3B801SX Series Swing Barrier Quick Start Guide 57 ...

Страница 69: ...r IR Board Triggered 05 Upper IR Board 10 Offline 34 The Sixth IR Beam on Upper IR Board Triggered 06 Upper IR Board 11 Offline 35 The Seventh IR Beam on Upper IR Board Triggered 07 Upper IR Board 12 Offline 36 The Eighth IR Beam on Upper IR Board Triggered 08 Lower IR Board 1 Offline 37 The Ninth IR Beam on Upper IR Board Triggered 09 Lower IR Board 2 Offline 38 The Tenth IR Beam on Upper IR Boar...

Страница 70: ... The Eighth IR Beam on Lower IR Board Triggered 20 Light Board Offline Entrance 49 The Ninth IR Beam on Lower IR Board Triggered 21 Light Board Offline Exit 50 The Tenth IR Beam on Lower IR Board Triggered 22 IR Adapter Offline Up 51 The Eleventh IR Beam on Lower IR Board Triggered 23 IR Adapter Offline Low 52 The Twelfth IR Beam on Lower IR Board Triggered 24 CAN Bus Exception 53 Upper IR Board 1...

Страница 71: ...ikvision access control and video intercom devices Figure F 1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices Figure F 2 Device Command DS K3B801SX Series Swing Barrier Quick Start Guide 60 ...

Страница 72: ...UD22971B ...

Отзывы: