User Manual of Network Fisheye Camera
43
Steps:
1.
Enter RS-232 Port Setting interface:
Configuration> System > System Settings > RS232
Figure 5-7
RS-232 Settings
Note:
If you want to connect the camera by the RS-232 port, the parameters of
the RS-232 should be exactly the same with the parameters you configured here.
2.
Click
Save
to save the settings.
5.2.4
RS-485 Settings
Purpose:
The RS-485 serial port is used to control the PTZ of the camera. The configuring of
the PTZ parameters should be done before you control the PTZ unit.
Note:
RS-485 settings vary according to the camera model.
Steps:
1.
Enter RS-485 Port Setting interface:
Configuration> System > System Settings > RS485
2.
Set the RS-485 parameters.
By default, the Baud Rate is set as 9600 bps, the Data Bit is 8, the stop bit is 1
and the Parity and Flow Control are None.
3.
Click
Save
to save the settings.
Note: