Camera Link Line Scan Camera
·
User Manual
23
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Line Start or Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3.
Select specific lines as Trigger Source according to actual demands.
Figure 7-6
Set Hardware Trigger
7.6.3 Set Shaft Encoder Control
If the camera enables the line trigger, you can select Encoder Module Out as trigger source. At this
time, the camera will receive signal A and signal B with phase difference. After internal computing,
the outputted signal can be used as camera’s trigger signal. The function demonstration of shaft
encoder module is shown below.
Phase A
Phase B
Line Inp ut 1
Line Input 2
Line input 1 is
selected as the
input signal for
phase A
Line input 2 is
selected as th e
input signal for
phase B
Phase A Input
Phase B Input
Shaft Encod er
Software
Module
Line Trigger
Module
Output
The final output
of module is line
trigger s ignal
Figure 7-7
Function Demonstration
The advantages of shaft encoder are as follows:
Encoder output pulse frequency is proportional to rotating speed.
The output pulse acts as a trigger signal for line scan camera.
Synchronize acquisition speed and sample movement of camera.
Non-uniform motion can also be a perfect match.
A trigger signal can be set as acquiring multiple lines or multiple frames with adjustable ratio.
Содержание MV-CL042-91CC
Страница 1: ...Camera Link Line Scan Camera User Manual ...
Страница 95: ...Camera Link Line Scan Camera User Manual 86 Figure 11 14 Update Firmware via USB Data Cable ...