Camera Link Line Scan Camera
·
User Manual
108
Parameter
Command
Value
Description
0—read
1—write
the device. E.g., set read
mode, w FileOpenMode 0
r FileOpenMode
Read
FileOperationSelector on
the selected file.
PayloadSize
r PayloadSize
Provides the number of
bytes transferred for each
data buffer or chunk on
the stream channel.
CounterSelector
/
/
The associated node is
controlled by XML, and
you do not need to set the
camera.
CounterEventSource w CounterEven0
11
11—Line0
/
CounterResetSource w CounterRese0
3
3—Software
/
CounterReset
w Count0 1
/
It resets counter and it can
be executed when
selecting Software as
Counter Reset Source.
CounterValue
w Count0 1234
/
Range 1 to 32767.
CounterCurrentValu
e
/
/
It cannot be configured.
Read only.
SuperPaletteEnable
w SuperPaletteEnable 1
/
/
SuperPaletteSelecto
r
/
/
The associated node is
controlled by XML, and
you do not need to set the
camera.
SuperPaletteHue
w SuperPal0
128
/
Range 0 to 255.