Camera Link Line Scan Camera
·
User Manual
17
Executing the reading or writing command is as follows.
Table 6-5
Command for Writing or Reading
Command for writing:
The following example is to set the exposure as 1000 us.
Command:
w ExposureTime 1000 <\r>
Returned value:
Success! <\r> <\n> (Setting succeeded.)
Failed! <\r> <\n> <\r> <\n> or Wrong input format. <\r> <\n> (Setting failed.)
Command for reading:
The following example is to get the exposure as 1000 us.
Command:
r ExposureTime <\r>
Returned value:
Success! <\r> <\n> <\r> <\n> or get ExposureTime: 1000 <\r> <\n> (Reading
succeeded.)
Failed! <\r> <\n> <\r> <\n> or Wrong input format. <\r> <\n> (Reading failed.)