ID3000 Series Smart Code Reader User Manual
49
Figure 8-31 Stop Trigger via TCP
Stop Trigger via Timeout Duration
Note
TimeOut Stop Trigger Enable is only available when the device mode is set to Normal and the
Trigger Mode is On.
When the trigger time reaches the specified maximum value (in ms), the trigger will be stopped.
You can enable TimeOut Stop Trigger Enable, and set Maximum Output Limited Time according
to actual demands. The range of Maximum Output Limited Time is 0 to 10000 ms.
Figure 8-32 Stop Trigger via Timeout Duration
Stop Trigger via Code Number
Note
CodeNum Stop Trigger Enable is only available when the device mode is set to Normal and the
Trigger Mode is On.
This function means that the code quantity outputted by the device is restricted to the settings
you configured here. You can enable CodeNum Stop Trigger Enable, and set CodeNum Stop
Trigger Min and CodeNum Stop Trigger Max according to actual demands.
●
If the outputted code quantity is smaller than configured CodeNum Stop Trigger Min, and the
device will output codes continuously.
●
If the outputted code quantity is smaller than configured CodeNum Stop Trigger Max, and the
device will stop outputting codes.
●
If the outputted code quantity is between configured CodeNum Stop Trigger Min and
CodeNum Stop Trigger Max, and the device will read and output codes according to trigger
signals.
●
If CodeNum Stop Trigger Min is same with CodeNum Stop Trigger Max, and the device will stop
outputting codes when the number of outputted codes reaches the configured number.