English
11
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
Condition
Cause
Remedy
Engine does not
start
Fuel
system
Fuel tank is empty or fuel level is low
Fill the fuel tank with the correct fuel mix
(25:1-50:1)
Fuel tank contains old fuel (o
ff
ensive
odor)
Replace with new fuel
Too much fuel is absorbed and spark
plug is wet
1. Disconnect the spark plug and allow to dry
2. Pull the starter handle 5 or 6 times to
remove the surplus fuel
3. Attach the spark plug
4. Set the choke lever to RUN position and
pull the starter handle
Fuel
fi
lter is clogged with dirt
Clean the fuel
fi
lter
Fuel pipe is bent or disconnected
Ensure that the fuel
fl
ows smoothly
Carburetor malfunction
Contact HiKOKI Authorized Service Centers
Electrical
system
Stop switch lead has short-circuited
Contact HiKOKI Authorized Service Centers
Spark plug is dirty
Replace or clean the spark plug
Electrode gap is too big
Adjust the gap to 0.6mm
Poor connection between high tension
cable and spark plug
Reconnect
Electrical system malfunction
Contact HiKOKI Authorized Service Centers
Other
Mu
ffl
er exhaust port is clogged with
carbon
Contact HiKOKI Authorized Service Centers
Engine starts
but cuts out
straightaway
Engine is apt to
cut out
Fuel
system
Fuel tank is empty or fuel level is low
Fill the fuel tank with the correct fuel mix
(25:1-50:1)
Fuel tank contains old fuel (o
ff
ensive
odor)
Replace with new fuel
Two-cycle oil has not been added
Contact HiKOKI Authorized Service Centers
Choke lever is in START position
Set the choke lever to RUN position
Air has got into fuel system
Reconnect the fuel pipe or joint
Carburetor malfunction
Contact HiKOKI Authorized Service Centers
Electrical
system
Ignition failure
Spark plug failure
Replace with new spark plug
Electrical system failure
Contact HiKOKI Authorized Service Centers
Other
Engine overheating
Wrong spark plug model
Replace with designated part
See “SPECIFICATIONS”
Dirty air cleaner
Clean
Carbon clogging (mu
ffl
er exhaust port)
Clean
Insu
ffi
cient compression (piston, piston
ring, cylinder)
Contact HiKOKI Authorized Service Centers
Abnormal vibration
Handle, handle bracket or other
fastening part is loose
Check and tighten
Blade is bent or damaged
Contact HiKOKI Authorized Service
Centers
Grease level is low in the gear case
Re
fi
ll the grease
See "maintenance of Gear case"
Blade clearance is too large
Adjust the blade clearance
See "maintenance of Cutting blade"
000Book̲CH24EAP.indb 11
000Book̲CH24EAP.indb 11
2019/01/29 17:11:50
2019/01/29 17:11:50
Содержание CH 24EAP
Страница 191: ...191 000Book CH24EAP indb 191 000Book CH24EAP indb 191 2019 01 29 17 12 13 2019 01 29 17 12 13 ...
Страница 192: ...192 000Book CH24EAP indb 192 000Book CH24EAP indb 192 2019 01 29 17 12 13 2019 01 29 17 12 13 ...
Страница 193: ...193 000Book CH24EAP indb 193 000Book CH24EAP indb 193 2019 01 29 17 12 13 2019 01 29 17 12 13 ...