52
Enforcer V10 Programming Guide
NO.
TYPE
ACTIVE
RESTORE
0051
Line Fault
When Line Fault signalled by
communicator
When fault clears
0052
Mains Fail
After pre-set time without mains
power
On restoration of mains
0053
Battery Faults
When battery disconnected or
load fail detected
At next valid code entry
0054
Low Volts
When the input voltage from the
transformer is too low
When the control panel reads the
correct voltage.
0055
"Global Fault 1
(Faults: Modem, Battery,
Fuse, Line, Mains)"
At fault
When fault clears
0056
"Global Fault 2
(Faults: as above)"
Activates if fault occurs only
when system is armed
When all faults cleared
0058
Guard Code Used
When ‘guard’ code accepted
After 60 seconds
0059
Engineer Access
When entering Engineer Mode
Leaving Engineer Mode
0060
Initialise Digi
At power up
Live for 45 seconds only
0063
Test ATE/GSM
Test signalling through PSTN and
GSM. Activates when a test call is
sent.(Only used for specific GSMs)
When test completed
0064
"Test ATS
For use with ATE
complying with BSIA
Form 175 to initiate
test call to ARC by each
available path."
Test signalling through PSTN and
GSM. Activates when a test call
is sent.
When test completed
0066
ATE not used
N/A
N/A
0170-
0199
User Defined 1-30
Can be used to trigger outputs via the keyfob. For example, an output
can be programmed as type ‘[0171] User Defined 02’ and then wired
to a garage door. If a user keyfob button is programmed as ‘[0171]
User Defined 02,’ when that button is pressed, the output will trigger
opening the garage door.
0600-
0609
Timers 01-10
For future development
0610-
0619
Calendar 01-20
For future development
0620-
0639
Logic Gate 01-20
For future development
0640-
0649
Delay 01-10
For future development
1xxx
Follow Input xxx
When input is activated
When input clears