5. Usage of heater operative mode switch and time/temp control
A. Proofread time: Press H to adjust hour. After several blinking, it will confirm automatically.
The same as M to adjust minutes.
B. Power-on by alarm: ( at most 24 hours)
Pressing prepare to place, then pressing H, M button to set time. It will confirm automatically after
several blinking.
C. Power-off by alarm:
Press control time button, the display will blinking and then adjust power-off time (at most 5 hours, at
least 1 minutes). It will confirm automatically after several blinking.
D. After power on, press P button to let temperature work, use +/- button to adjust temperature. Do not
under timing control.
6. Temperature detector
For the recommendation of the
minimum installation distances,
please see installation diagram of
sauna heater for details.
A heater resistant cable of 3 meters
long is provided, which can be
extended to the outside of sauna
room by normal weak current cables.
For cables connection of the
thermostat, please see the following
figure.
7. Installation of temperature detector
8. Limit control
If the temperature is too high inside sauna room like the temperature controller break down, the
temperature limiter in the temperature detector will cut power off and reset automatically after trouble
9. Power connection
A. Connect the phase line to controller power input end L1, L2, L3 respectively. Null
line (neutral line) connect to input end N, protective earth wire attach to
〨
.
B. Use the heat resistant conductor to connect the controller power output and with
the heater input end according to the same symbol.
(1) Use screwdriver to remove
the cover at the edge of the
(2) Fix the detector circuit
board upon the sauna heater
(3) Fix the cover on the
detector circuit board.
Front side
Back side